Hampton Direct H25-NG1, H25-LP1 installation manual Installation, V H1

Models: H25-NG1 H25-LP1

1 44
Download 44 pages 38.92 Kb
Page 16
Image 16
V

INSTALLATION

Vertical Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option V

H

V + V1 With these options, max. total

A)1' Min. 4' Max. 2' Min. pipe length is 30 feet with min.

B)2' Min. 5' Max. 3' Min. of 6 feet total vertical and max. 8 feet total horizontal.

C)

3' Min.

6' Max.

4' Min.

Please note min. 1 foot

D)

4' Min.

7' Max.

5' Min.

between 90o elbows is re-

E)

5' Min.

8' Max.

6' Min.

quired.

V1

Lengths do not include elbow indicated

Vent restrictor position A (fully open), refer to the "Vent

Restrictor Position" section.

Vertical Venting with Two (2) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

H + H1

V

 

With these options, max. total

A)

2' Max.

2' Min.

 

pipe length is 30 feet with min.

B)

3' Max.

3' Min. of 6 feet total vertical and max.

 

 

 

 

6 feet total horizontal.

C)

4' Max.

4' Min.

 

Please note min. 1 foot

D)

5' Max.

5' Min.

 

between 90o elbows is

E)6' Max. 6' Min. required.

Lengths do not include elbow indicated

Vent restrictor position A (fully open), refer to the "Vent

Restrictor Position" section.

V

H1

H V

H

16

Hampton® H25-1 Direct Vent Freestanding Gas Stove

Page 16
Image 16
Hampton Direct H25-NG1, H25-LP1 installation manual Installation, V H1