Hampton Direct U32 installation manual Log Set Installation, Vermiculite and Embers

Models: U32

1 40
Download 40 pages 16.33 Kb
Page 10
Image 10
LOG SET INSTALLATION

INSTALLATION

LOG SET INSTALLATION

Read the instructions below carefully and refer to the images. Dangerous operating conditions may occur if the logs are not positioned in their correct locations. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.

2)Spread vermiculite around the exposed firebox base. Then take some embers and spread them over the vermiculite as shown.

IMPORTANT

For LP units the Air Deflector MUST be installed prior to log installation. See "Conversion from NG to LP" section in manual for installation instructions.

Log kit (Part # 425-930) contains the following pieces:

a)

27-31

Rear Log

b)

27-32

Middle Left Log

c)

27-33

Front Log

d)

27-34

Middle Right Log

e)

27-35

Left Log

f)

27-36

Right Log

g)

902-154

Embers Lava

h)

902-179

Vermiculite

i)

902-153

Rock Wool

j)946-669 Platinum Embers (supplied with packaged manual)

Vermiculite and Embers

3)Fit log 27-31 into the pins on the rear log tray.

27-36

27-35

 

 

27-34

27-32

27-33

27-31

27-31

4)Fit log 27-32 into the pins on the middle left hand side of the burner.

1)Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position.

27-32

10

U32-5 FPI Direct Vent Gas Insert

Page 10
Image 10
Hampton Direct U32 installation manual Log Set Installation, Vermiculite and Embers