Hampton Direct Installation, For P36D-1 / P36-4Only, For U32-5Only, Chain, Heat Shield

Models: U32

1 40
Download 40 pages 16.33 Kb
Page 19
Image 19
Chain

INSTALLATION

25)Locate the ground lug.

For P36D-1 / P36-4 Only:

25a) By the receptical box, left of the unit.

28)Install the 1/2" bushing to the heat shield.

29)Plug the DC spark generator wires to the DC Sparker.

32)Mount the heat shield to the DC Sparker. Secure into place with the velcro, which is provided in the kit.

33)Find a location which is not too hot and is easy to reach for changing the battery. Note: It should be kept away from the

chain.

Chain

For U32-5 Only:

25b) Located on the left side of the unit.

30) Connect the ground wire to the DC Sparker mounting bracket.

26)Connect one end of the supplied green ground wire to the lug with the nut and washer from the kit.

Ground

wire from

kit

34)Tie up the loose wires with the wire clip.

27)Run the other end of the ground wire and DC spark generator wires through the bushing on the heat shield.

Heat Shield

31)Install the supplied battery into the DC Sparker Box by opening the battery compartment.

Battery

Compartment

35)Check for gas leaks.

36)Check inlet and outlet pressures.

37)Check operation of flame control.

38)Check for proper flame appearance and glow on logs.

NOTE: The battery in the DC Sparker Box will need to be replaced an- nually.

U32-5 FPI Direct Vent Gas Insert

19

Page 19
Image 19
Hampton Direct Installation, For P36D-1 / P36-4Only, For U32-5Only, Chain, Ground wire from kit, Heat Shield