MAINTENANCE

MAINTENANCE

Top View of pilot fl ame

Incorrect fl ame pattern will have small, probably yellow fl ames, not coming into proper contact with the rear of the burner or thermopile.

Top View of pilot fl ame

If you have an incorrect fl ame pattern, contact your FPI dealer for further instructions.

GENERAL VENT

MAINTENANCE

Conduct an inspection of the venting system semi-annually. Recommended areas to inspect as follows:

1)Check the Venting System for corrosion in areas that are exposed to the elements. These will appear as rust spots or streaks, and in extreme cases, holes. These components should be replaced immediately.

2)Remove the Termination Cap, and shine a fl ashlight down the Vent. Remove any bird nests, or other foreign material.

3)Check for evidences of excessive condensation,suchaswaterdropletsforming in the inner liner, and subsequently dripping out the joints, Continuous condensation can cause corrosion of caps, pipe, and fi ttings. It may be caused by having excessive lateral runs, too many elbows, and exterior portions of the system being exposed to cold weather.

4)Inspect joints, to verify that no pipe sections or fi ttings have been disturbed, and consequently loosened. Also check mechanical supports such as Wall Straps, or plumbers' tape for rigidity.

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagram under Log Installation.

NOTE: Improper positioning of logs may create carbon build-up and will alter the unit’s performance which is not covered under warranty.

GOLD-PLATED TRIM

The 24 carat gold plated fi nish on the trim requires little maintenance, and need only be cleanedwithadampcloth.DONOTuseabrasive materials or chemical cleaners, as they may harm the fi nish and void the warranty. Clean any fingerprints off before turning the unit on. If the top louvers start to discolour, check the door gasket seal and replace if necessary.

DOOR GLASS

YourFPI insertissuppliedwithhightemperature, 5mmNeoceramceramicglassthatwillwithstand the highest heat that your unit will produce. If your glass requires cleaning, we recommend using an approved glass cleaner available at all authorized dealers. Do not use abrasive materials. Do not clean the glass when hot.

In the event that you break your glass by impact, purchase your replacement from an authorized FPI dealer only, and follow our step-by-step instructions for replacement.

Warning: Do not operate appliance withglasspanelsremoved,cracked orbroken.Replacementoftheglass should be done by a licensed or qualified service person.

Caution: Wear gloves when removing damaged or broken glass.

Flush Glass Replacement

Remove the fl ush door front (as per instructions in section "Standard Flush Doo"). Remove the 4 glass clips from each corner. Slide in the new replacement glass. Push the 4 glass clips back onto the frame.

GLASS GASKET

If the glass gasket requires replacement use glass gasket (Part # 936-265) for the Bay Front and a tadpole gasket for the Flush Front (Part

# 936-155).

U32-5 FPI Direct Vent Gas Insert

31