Page 19For technical questions, please call 1-800-444-3353.SKU 67596
Fuel Filter replacement (if equipped)
warning! risK OF Fire
Or exPLOsiOn. Replace the
fuel lter in a well-ventilated
area away from ignition
sources. Do not smoke.
Wait for engine to cool completely 1.
before proceeding.
Wear protective gear including, ANSI-2.
approved safety goggles, NIOSH-
approved dust mask/respirator, and
nitrile gloves.
Close fuel valve leading from gas 3.
tank completely.
Take note of the fuel lter’s 4.
orientation.
Place a suitable container under the 5.
fuel lter.
Disconnect the fuel lines leading to 6.
and from the fuel lter and allow fuel
to drain onto the container.
Install new fuel lter in the same 7.
orientation. Make sure to properly
secure both fuel lines.
Clean up and properly dispose of all 8.
fuel.
Wait for at least one hour before use 9.
to allow all residual fuel vapors to
dissipate. to prevent Fire, do not
start the engine while the smell of
fuel hangs in the air. Remember to
open the fuel valve before restarting
the engine. It may take a little
longer than usual to start the engine
because the fuel needs to rell the
fuel line and new lter.
cleaning, Maintenance, and Lubrication schedule
note: This maintenance schedule
is intended solely as a general
guide. If performance decreases
or if equipment operates unusually,
check systems immediately. The
maintenance needs of each piece
of equipment will differ depending
on factors such as duty cycle,
temperature, air quality, fuel quality,
and other factors.
note: These procedures are in addition to
the regular checks and maintenance
explained as part of the regular
operation of the engine and
equipment.
after 20 Operation Hour Break-in
Period:
Change engine oil.a.
after every 25 Operation Hours:
Clean/replace air lter element.a.
Inspect/clean spark plug.b.
Blow out water lters.c.
after every 50 Operation Hours:
Change engine oil.a.
Replace fuel lter (if equipped).b.
after every 100 Operation Hours:
Replace spark plug.a.
Replace air lter element.b.
Change pump oil.c.
note: All maintenance procedures
scheduled for 25, 50, and 100
operation hours should be performed
at least yearly.