Controls And Setup
Note: Familiarize yourself with the loca- tion and function of all of the ma- chine’s controls before proceeding to setup of the machine.
Controls and features
1.This item is equipped with a GFCI (Ground Fault Circuit Interruption) plug. Read and follow these GFCI precautions:
WARNING! To prevent electric shock and death: Test GFCI (Ground Fault Circuit Interrupter) before each use as follows:
INDICATOR
RESET
BUTTON
TEST
BUTTON
FIGURE A
a. Make sure the trigger is released and plug GFCI into power out- let. Press reset button. Indicator should turn on.
b. Press test button. Indicator should turn off.
c. Press reset button again for use.
Do not use if above test fails.
The GFCI device does not protect against electrical shock due to contact with both circuit conduc-
tors or a fault in any wiring supply- ing this device.
Should replacement of the GFCI Power Plug become necessary, only a qualified technician should perform the service.
Do not alter or disable the GFCI Power Plug.
To allow GFCI unit to function properly, extension cords must not be used with this pressure washer.
Spray | Pressure |
Control | Control |
Sleeve | Sleeve |
FIGURE B
2.The Spray Control Sleeve on the Spray Wand can be rotated for a range of spray patterns, from a full fan spray to a direct stream spray. Also, the Pressure Control Sleeve can be rotated clockwise for low- pressure spray and detergent appli- cation, or rotated counterclockwise for normal
3.The
SKU 99741 | For technical questions, please call | PAGE 10 | |