Shut off the Pressure Washer, release all pressure in a safe manner, and disconnect it from power and water before adjusting, cleaning, or repairing the unit.

Problem: There is no water coming out of the spray gun when the pump is run- ning and trigger is depressed.

Cause: Hard water deposits (calcium) has built up inside the small orifices block- ing the water from entering the pump.

Solution: Unplug the unit, lay the unit face down, fill pump at the water inlet fitting with calcium remover (such as CLR) and allow at least 5 hrs for calcium deposit to break down.

REV 08h

If the steps above do not solve the problem or if the repairs involved are

too complex, contact a qualified technician.