Hearth and Home Technologies Cyclone-BN Vent Diagrams, Top Vent Horizontal Termination One Elbow

Models: Cyclone-BN Cyclone-BC

1 48
Download 48 pages 11.24 Kb
Page 13
Image 13

D. Vent Diagrams

WARNING

Fire Risk. Explosion Risk.

Do NOT pack insulation or other combustibles between ceiling firestops.

ALWAYS maintain specified clearances around venting and firestop systems.

Install wall shield and ceiling firestops as specified.

Failure to keep insulation or other material away from vent pipe may cause fire.

1. Top Vent - Horizontal Termination

One Elbow

NOTE: There MUST be a 25%

 

reduction in total H when using

 

flex vent except when using the

 

simple up and out installation

 

(see Figure 5.7).

HT

VT Min.

HT Max.

1.5

ft.

2

ft.

2.5

ft.

5

ft.

3.5

ft.

8

ft.

4.5 ft.

11 ft.

VT + HT = 40 ft. Max

VT

Figure 5.3

Two Elbows

H2

NOTE: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 5.7).

H1VT

H1

H2

VT Min.

HT Max.

*

*

1.5

ft.

2

ft.

 

 

 

 

 

 

*

*

2.5

ft.

5

ft.

*

*

3.5

ft.

8

ft.

*

*

4.5 ft.

11 ft.

VT + HT = 40 ft. Max.

*No specific restrictions on this value EXCEPT VT + HT cannot exceed 40 ft. Max.

Figure 5.4

Heat & Glo • Cyclone-BN, Cyclone-BC2073-900 Rev. N • 10/08

13

Page 13
Image 13
Hearth and Home Technologies Cyclone-BN Vent Diagrams, Top Vent Horizontal Termination One Elbow, Two Elbows, Min Max