2. Top Vent - Vertical Termination - (continued) Two Elbows
HT
V2
V1
Three Elbows
V2
H2 | H1 |
|
Figure 5.8
V1 | V2 | VT Min. | HT Max. | ||
* | * | 1.5 | ft. | 2 | ft. |
* | * | 2.5 | ft. | 5 | ft. |
* | * | 3.5 | ft. | 8 | ft. |
|
|
|
| ||
* | * | 4.5 ft. | 11 ft. | ||
|
|
|
|
|
|
VT + HT = 40 ft. Max.
*No specific restrictions on this value EXCEPT
VT + HT cannot exceed 40 ft. Max.
NOTE: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 5.7).
V1 | H1 | H2 | V2 | VT Min. | HT Max. | ||
* | * | * | * | 1.5 | ft. | 2 | ft. |
* | * | * | * | 2.5 | ft. | 5 | ft. |
|
|
|
|
|
|
|
|
* | * | * | * | 3.5 | ft. | 8 | ft. |
|
|
|
|
|
| ||
* | * | * | * | 4.5 ft. | 11 ft. |
VT + HT = 40 ft. Max.
*No specific restrictions on this value EXCEPT
VT + HT cannot exceed 40 ft. Max.
NOTE: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 5.7).