C. Hot Surface Ignition Wiring

This appliance requires a 110 VAC supply to the appliance terminal block for operation. A wiring diagram is shown in Figure 10.3.

This appliance is equipped with a 24V valve.

Optional Accessories Requirements

Wiring for optional accessories should be done now to avoid reconstruction.

CAUTION

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

WARNING

Shock hazard.

Replace damaged wire with type 105º C rated wire.

Wire must have high temperature insulation.

 

 

 

GROUND

FAN MOTOR

 

 

 

 

 

 

 

(L1) 120-BLACK

 

 

 

 

(N) NEUTRAL-WHITE

 

REMOTE

 

 

 

 

 

8

 

 

 

 

 

24 VOLT TRANS

3

 

 

2

 

 

2

 

 

 

 

 

 

1

5

 

 

 

 

SENSOR

 

 

 

 

 

 

 

9

 

7

6

 

 

 

 

 

 

 

 

 

CONTROL MODULE

 

 

 

 

4

 

 

HOT SURFACE IGNITOR

1

 

3

 

(HSI)

 

 

 

 

 

 

ITEM

PART DESCRIPTION

 

COLOR(S)

1

(M)L1 - (M)F1 - (T) 23 -

-120V

 

Black

2

(FT) BTM-IGN-(T)1- +120V

 

Black/White

3

(V)1 & (V)3 - GND & (T)4

 

Blue/Green

4

(V)2 & (V)4 - (M)MV1

 

 

Red

5

(M) F2 - (FT) TOP

 

 

White

6

(M)S1-IGN

 

 

White

7

FEMALE RECEPTACLE PLUG

 

Black/White/Green

8

REMOTE WITH PIGTAIL - (M)W OPTIONAL

 

Red

9

(M)R - (M)W - (M)P.SW - REM/WS

 

Red

Figure 10.3 Wiring diagram

 

 

 

 

 