2. Top Vent - Vertical Termination

No Elbow

CAP

VT MAX.

40 ft.

Note: Depending on the vent run an exhaust baffle may be required to ensure best flame appearance. See Section 7.B for baffle installa- tion instructions.

VT

Figure 5.6

Flex Vent

The flex vent must be supported with the spacing between support intervals not exceeding 4 feet, with no more than ½ inch sag between supports.

A support is required at each change in venting direction, and in any location where it is necessary to maintain the necessary clearance to combustibles. A simple “up and out” installation requires only enough support to maintain the necessary clearance to combustibles. However, the vent attachment point and the firestop location are con- sidered to be supports.

 

TERMINATION

3 in. CLEARANCE

CAP

FLEX-VENT

1 in.

CLEARANCE

Figure 5.7