1. Top Vent - Horizontal Termination - (continued)

Three Elbows

Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 7.3).

V1 Minimum**

H1 Maximum

H1 + H2 Maximum

90 Elbow Only**

1-1/2 ft.

457 mm

2 ft.

610 mm

1/2 ft.**

152 mm

1-1/2 ft.

457 mm

4 ft.

1.2 m

 

 

 

 

 

 

1-1/2 ft.

457 mm

3 ft.

914 mm

6 ft.

1.8 m

 

 

 

 

 

 

2-1/2 ft.

762 mm

5 ft.

1.5 m

10 ft.

3.0 m

3-1/2 ft.

1.1 m

7 ft.

2.1 m

14 ft.

4.3 m

4-1/2 ft.

1.4 m

14 ft.

4.3 m

14 ft.

4.3 m

 

 

 

 

 

 

H1 + H2 MAX. =14 ft. (4.3 m)

V1 + V2 + H1 + H2 MAX. = 40 ft. (12.2 m)

** See Warning Below.

H2

Note: Use SLP Series components only.

V2

H1

V1

WARNING**

Fire Risk.

When using SLP-HRC-SS and SLP-HRC-ZC- SS termination caps on top vented fireplaces, a one foot minimum vertical vent section is

required before installing first elbow.

Figure 7.6

26

Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. F • 9/12

Page 26