4.Rear Vent - Vertical Termination One Elbow

Note: Use DVP Series components only.

V1

 

V1 MIN.

H1 MAX.

1 ft.

 

305 mm

3-1/2 ft.

1.1 m

 

 

 

 

 

2 ft.

 

610 mm

5-1/2 ft.

1.7 m

 

 

 

 

 

3 ft.

 

914 mm

7-1/2 ft.

2.3 m

 

 

 

 

 

H MAX. = 7-1/2 ft. (2.3 m)

V1 + H1 MAX. = 40 ft. (12.2 m)

H1

Figure 7.16

Note: Use DVP Series components only.

Two Elbows

V1

H1 + H2 MAX

V1 MIN.

Back to back elbows

1/2 ft.

152 mm

 

 

 

 

2-1/2 ft.

762 mm

1 ft.

305 mm

 

 

 

 

4-1/2 ft.

1.4 m

2 ft.

610 mm

 

 

 

 

6-1/2 ft.

2.0 m

3 ft.

914 mm

 

 

 

 

H MAX. = 6-1/2 ft. (2 m)

V + H+ H1 MAX. = 40 ft. (12.2 m)

INSTALLED

HORIZONTALLY H1

H2

Figure 7.17

32

Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 Rev. F • 9/12