2. Top Vent - Vertical Termination
Top Vent - Vertical Termination
No Elbows
V1 = 60 ft. Max. (18.3 m)
Note: If installing a vertical vent/termination off the top of the appliance, the optional vertical termination baffle may be needed.
Note: Use SLP Series |
components only. |
CAP |
V1 |
Figure 7.7 |
Exhaust restrictors are recommended for these verti- cally terminated products which have excessive draft. Exhaust restrictors will compensate for high draft, and restore visual flame height. If the vent configuration has a total vertical of
Exhaust restrictor Instructions
1.Install the exhaust restrictor over the center of the ex- haust outlet in the firebox (see Figure 7.8).
2.Center the exhaust restrictor in the open end of the exhaust outlet and secure through the slots on the ex- haust restrictor with the
EXHAUST BAFFLE
To access the exhaust openings, remove the ex- haust baffle. To remove exhaust baffle, remove the two wing nuts.
Top Vent Application
Exhaust restrictor
Rear Vent Application
Exhaust restrictor
Note: Be sure to rein- stall the exhaust baffle after exhaust restrictor installation.
Figure 7.8