Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07
10
A
B
C
D
E
7.6 cm
1.3 cm
AB CDE
86.4cm 41.3cm 72.8cm 100.1cm 141.6cm
*
Figure 2. Fireplace Dimensions, Locations, and
Space Requirements
3
Installing the
Fireplace
The diagram below shows space and clearance
requirements for locating a fireplace within a room.

Step 1

Locating the

Fireplace

Figure 3. Heat Shield
NOTE:
Dimensions are
shown with the
sides, back
and/or corners
of the unit 1/2
inch from the
wall.
The heat shield must be
attached as shown if
combustible materials
are placed directly on
top standoffs (Figure 3).
The minimum clearance
to a perpendicular wall
extending past the face
of the fireplace is 7.62cm.
The back of the fireplac-
es may be recessed
into combustible con-
struction, as shown
below.
MODEL: SL-350TRS-CE-D RECESSED DEPTH: 41.3cm

Clearance Requirements

The top and back of the
fireplace are defined by
stand-offs.
Minimum Clearances from the Fireplace to Combustible Materials
Glass
Front Floor Back of
Fireplace Sides of
Fireplace Top of
Fireplace Ceiling
91.4cm 0 1.3cm 1.3cm 3.8cm 79cm
TOP STANDOFFS
HEAT SHIELD
HEAT SHIELD
INSTALLED