Clearance Diagrams - 36” Legacy

Metro / Legacy Series

Clearance Diagrams - 36” Legacy

Dim

36" Legacy

 

A1

28 3/4" (73cm)

 

to front of stove

 

 

 

A2

31 1/2" (80 cm)

 

to edge of oven door handle

 

 

 

B

36 1/8" (92cm)

 

C

36" (91cm)

 

D

17 1/2" (45cm)

 

E1

standard 42 1/8 "(106cm)

 

E2

low profile: 38" (97cm)

 

E3

high back w/ shelf:

 

56 1/8" (143cm)

 

 

Figure 1

 

Table 1

Clearances

Minimum distance between the range and a side wall above the cooking top surface is 6” (see dim "O" in Table 2 below)

0” Clearance to the back of the stove may be obtained when installing the appliance against a non - combustible wall or with the installation of our Splashback Kit. Responsibility for ensuring that the rear wall is non - combustible lies with the owner or end user. (check local building codes) - if wall behind stove is deemed combustible and our splashback kit is not installed, then the minimum spacing from the back of stove to nearest combustible wall is 6”

Electrical requirements:

 

For proper performance a 900 CFM vent

• Electrical hookup must be done by a licenced electrician

hood is required on all 36" Metro ranges

• 240 Volts 60Hz 5.6 kW

3 prong plug for U.S. and 4 prong for Canadian installations.

to ensure adequate and proper ventila-

(5 ft-1.5 m power cord included) New installations for the U.S. may require a four prong

tion. For superior ventilation we

plug, please confirm prior

to ordering.

recommend using a 42” hood, however

a 36” hood is adequate.

 

 

 

 

 

Gas Requirements:

Gas hook-up must be done by a licensed gas fitter.

Pressure requirements: Natural gas: 6” W.C. (min); LP gas: 11” W.C. (min)

• Connection: 1/2” NPT • 5/8” minimum diameter flex line.

• An accessible

manual

shut

off

Dim

36" Legacy

 

 

 

 

 

Q

 

 

valve must be in-

G

Maximum 26"" (66cm)

 

 

 

 

 

 

 

stalled at the appli-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Edges of

ance.

 

 

H

36" (92.5cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

counter top

• Natural Gas/Pro-

I

12" (30.5cm)

 

 

 

R

 

 

 

m ust be finishe d

 

 

 

 

 

 

O

pane Conversion

 

 

 

 

 

 

 

 

J

37" (94cm)

*

 

 

 

 

 

 

kits are available -

 

 

 

 

 

 

G

must be done by a

K

5 5/8"(14.5cm)

 

P

 

S

 

 

 

licensed gas fitter

L

2" (5cm)

 

 

 

1

 

 

 

 

 

 

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cupboard depth

 

 

 

M

 

 

 

 

 

 

 

 

Anti Tip Bracket:

18" (46cm)

 

 

 

 

 

Anti-tip

 

m ust not exceed

 

 

 

 

 

 

 

 

H 26”

N

16" (41cm)

 

 

 

 

 

bracket

 

Bracket included

 

 

 

 

 

 

 

 

 

 

 

 

T

 

 

 

 

 

with every stove.

O

6" (15cm) min left and right side

 

N

 

 

 

 

 

 

K

 

 

J

When properly in-

P

13" (33cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

stalled, will prevent

Q

SPECIFY WIDTH OF HOOD

 

 

 

 

 

 

M

stove from tipping

 

 

 

 

 

 

 

 

 

 

 

G as Inlet

 

 

 

forward

if down-

R

24" (61 cm)

 

 

 

 

 

 

 

 

 

L

 

 

 

Note: If range must stand beside

ward force is ap-

 

30" min to 36" max (76-92 cm)

 

 

 

 

 

S

 

 

 

 

 

I

a refrigerator, it is important for

plied to an open

for standard and high back guard

 

 

 

 

 

 

 

 

 

 

 

proper air circulation.There must

door.

 

 

 

30" min to 32" max (76-82 cm)

 

 

 

 

 

 

 

 

S1

 

 

 

 

 

 

be at least 5” (125 mm) of space

 

 

 

 

for low profile back guard only

 

 

 

 

 

 

between the two appliances.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

18" (45cm)

 

 

 

 

 

 

 

 

*U.S. models only: J=36 1/2”

6