![Gas Trouble Shooting Chart](/images/new-backgrounds/70967/70967103x1.webp)
Section 8: Troubl Shooting
Gas Trouble Shooting Chart
Note: Random sparking after burner lights or uneven flame from burner - please refer to page 36 for proper burner assembly (burner rings not properly positioned on burner base). Some ticking is normal from time to time.
P ro b le m | C a u se | R e m ed y | |
|
|
| |
N o sparks w hen |
|
| |
any control knob | N o pow er to spark m odule - | Check electrical supply to spark m odule | |
is turned to | m odule sw itch faulty | w ith voltm eter - replace m odule | |
“light” |
|
| |
|
|
| |
N o sparks w hen | Check high voltage w ires carefully for | ||
one or som e | |||
controlled by knob sw itch is | loose connections or pinches in the | ||
control knob(s) is | |||
grounded or has a high | w ires; if connections are tight, replace | ||
(are) turned to | |||
resistance leak | high voltage w ire | ||
“light” | |||
|
| ||
|
|
| |
Sparking occurs at |
|
| |
electrodes w hen | D isconnected sw itch lead or | Check all sw itch lead connections for | |
all control knobs | short in sw itch lead | looseness and w ires for dam age | |
are turned off |
|
| |
|
|
| |
| H igh resistance or open | Push receptacles firm ly onto all | |
| connection betw een spark | ||
| term inals | ||
| output term inal and H .V. w ire | ||
| Check positioning of shrink sleeving on | ||
| receptacle (spark w ill jum p | ||
| receptacle – should be flush w ith end of | ||
| sm all gap but sensing current | ||
| receptacle – trim if necessary | ||
| w ill not) | ||
A ll burners that |
| ||
|
| ||
are turned on | D efective m odule | Replace m odule | |
have lighted but |
|
| |
G round/Earth lead to m odule |
| ||
electrodes are still |
| ||
disconnected or range chassis |
| ||
sparking |
| ||
not properly connected to |
| ||
| Check ground/earth connection of range | ||
| ground/earth by ground/earth | ||
| chassis and ground/earth lead | ||
| lead or through third prong of | ||
| connection to m odule | ||
| pow er cord plug, com bined | ||
|
| ||
| w ith reversed pow er supply |
| |
| polarity |
| |
|
|
| |
Flam e jetting off |
| Reduce size of air shutter opening until | |
outer head burner | Too m uch air | ||
flam e is no longer jetting off burner | |||
ring or inner head | Pots too large | ||
head | |||
burner ring |
| ||
|
| ||
|
|
| |
N uisance sparking |
| Reduce size of air shutter opening until | |
w hen one or both | Too m uch air | ||
flam e is no longer jetting off burner | |||
grill burners are | Pots too large | ||
head.(Flam e jetting off burner) | |||
on |
| ||
|
| ||
|
|
|
49