E. Vent Diagrams

Top Vent - Horizontal Termination

One Elbow

V1 Minimum

H1 Maximum

1 ft.

305 mm

3 ft.

914 mm

 

 

2 ft.

610 mm

6 ft.

1.8 m

 

3 ft.

914 mm

9 ft.

2.7 m

 

4 ft.

1.2 m

12 ft.

3.7 m

 

V1 + H1 = 40 ft. (12.2 m) Maximum

 

 

H1 = 20 ft. (6.1 m) Maximum

 

V1

V1 = 1 ft. (305 mm) Minimum

 

 

 

 

H1

Figure 7.3

Two Elbows

V1 Minimum

H1 + H2 Maximum

1 ft.

305 mm

Cannot do

 

 

 

 

1 1/2 ft.

457 mm

1-1/2 ft.

457 mm

2 ft.

610 mm

3 ft.

914 mm

3 ft.

914 mm

6 ft.

1.8 m

 

 

 

 

4 ft.

1.2 m

9 ft.

2.7 m

 

 

 

 

V1 + H1+ H2 = 50 ft. (15.2 m) Maximum

H1 + H2 = 17 ft. (5.2 m) Maximum

V1 = 1 ft. (305 mm) Minimum

H2

V1

H1

 

 

INSTALLED

Figure 7.4

HORIZONTALLY

24

Heat & Glo • 8000CF-OAK-IPI2059-900 Rev. R • 6/09

Page 24
Image 24
Heat & Glo LifeStyle 8000CFLP-OAKIPI, 8000CF-OAK-IPI Vent Diagrams Top Vent Horizontal Termination One Elbow, Two Elbows