Heat & Glo LifeStyle 8000CFLP-OAKIPI, 8000CF-OAK-IPI I. Install Horizontal Termination Cap

Models: 8000CF-OAK-IPI 8000CFLP-OAKIPI

1 61
Download 61 pages 61.27 Kb
Page 40
Image 40
I. Install Horizontal Termination Cap

I. Install Horizontal Termination Cap

WARNING! Risk of Fire! The telescoping flue section of the termination cap MUST be used when connecting vent.

1-1/2 (38 mm) minimum overlap of flue telescoping section is required.

Failure to maintain overlap may cause overheating and fire.

• Vent termination must not be recessed in the wall. Siding

 

may be brought to the edge of the cap base.

Flash and seal as appropriate for siding material at

 

outside edges of cap.

When installing a horizontal termination cap, follow

Note: When using termination caps with factory-supplied heat shield attached, no additional wall shield firestop is required on the exterior side of a combustible wall.

 

HEAT SHIELD OR

HEAT SHIELD

 

EXTENDED

 

1-1/2 IN. (38 MM) MIN.

 

HEAT SHIELD

WALL SHIELD

OVERLAP

 

 

 

FIRESTOP

 

 

SLIP SECTION ANSI Z223.1 and CAN/CGA-B149 installation codes

CAN BE EXTENDED

the cap location guidelines as prescribed by current

ANSI Z223.1 and CAN/CGA-B149 installation codes

INNER VENT

OUTER VENT

SHEATHING

and refer to Section 6 of this manual.

CAUTION! Risk of Burns! Local codes may require in- stallation of a cap shield to prevent anything or anyone from touching the hot cap.

INTERIOR

EXTERIOR

VENT DEPTH FROM BACK OF APPLIANCE TO

Manual background OUTSIDE SURFACE OF EXTERIOR WALL

(SEE CHART BELOW)

Figure 10.16 Venting through the wall

Cap Specification Chart

(depth without using additional pipe sections)

 

DVP-TRAPK1

DVP-TRAP1

DVP-TRAPK2

DVP-TRAP2

 

Top Vent

Rear Vent

Top Vent

Rear Vent

 

Depth

Depth

Depth

Depth

 

4-1/8 in. to

N/A

6-5/8 in. to

N/A

 

6 in.

10-5/8 in.

8000

 

 

 

 

 

 

Series

 

 

 

 

DVP-HPC1

DVP-HPC1

DVP-HPC2

DVP-HPC2

 

 

Top Vent

Rear Vent

Top Vent

Rear Vent

 

Depth

Depth

Depth

Depth

 

4-1/8 in. to

N/A

6-1/8 in. to

N/A

 

6-1/4 in.

10-1/4 in.

 

 

 

DVP-TRAP1 can adjust 1-7/8 in. (4-3/16 to 6-1/16)

DVP-TRAP2 can adjust 4 in. (6-9/16 to 10-9/16)

DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8)

DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2)

40

Heat & Glo • 8000CF-OAK-IPI2059-900 Rev. R • 6/09

Page 40
Image 40
Heat & Glo LifeStyle 8000CFLP-OAKIPI, 8000CF-OAK-IPI owner manual I. Install Horizontal Termination Cap