Heat & Glo LifeStyle 8000CF-OAK-IPI Top Vent - Vertical Termination - continued, Two Elbows, V1 +

Models: 8000CF-OAK-IPI 8000CFLP-OAKIPI

1 61
Download 61 pages 61.27 Kb
Page 27
Image 27
Top Vent - Vertical Termination - (continued)

Top Vent - Vertical Termination - (continued)

Two Elbows

 

V1

H1 Maximum

V2

V1 + V2

Minimum

1 ft.

305 mm

3 ft.

914 mm

*

*

 

*

 

 

 

 

 

 

 

 

2 ft.

610 mm

6 ft.

1.8 m

*

*

 

*

 

 

 

 

 

 

 

 

4 ft.

1.2 m

12 ft.

3.7 m

*

*

 

*

V1 + V2 + H1 = 50 ft. (15.2 m) Max.

*No specific restrictions on this value EXCEPT V1 + V2 + H1 cannot exceed 50 ft. (15.2 m)

V2

Figure 7.11

H1

V1 = 1 ft. (305 mm) Min.

V1

Three Elbows

V2

 

V1

H1+ H2

V2

V1+ V2 Minimum

H1+ H2 Maximum

1 ft.

305 mm

3 ft.

914 mm

*

*

*

3 ft.

914 mm

2 ft.

610 mm

6 ft.

1.8 m

*

*

*

6 ft.

1.8 m

4 ft.

1.2 m

12 ft.

3.7 m

*

*

*

12 ft.

3.7 m

 

 

 

 

 

 

 

 

 

H1 + H2 = 17 ft. (5.2 m) Maximum

V1 + V2 + H1 + H2 = 50 ft. (15.2 m) Maximum

V1 = 1 ft. (305 mm) Minimum

H1

H2

V1

 

 

INSTALLED

 

HORIZONTALLY

Figure 7.12

Heat & Glo • 8000CF-OAK-IPI2059-900 Rev. R • 6/09