J. Lighting Instructions (Standing Pilot)
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
LIGHTING INSTRUCTIONS
1. | Open control access panel. |
2. | Turn off all electric power to |
| the appliance. |
3. | Push in gas control knob |
A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these in- structions exactly.
B.BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•DO NOT try to light any appliance.
•DO NOT touch any electric switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas sup- plier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, DO NOT try to repair it, call a qualified service technician. Force or attempted repair may re- sult in a fire or explosion.
D. DO NOT use this appliance if any part has been under water. Imme- diately call a qualified service tech- nician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
slightly and turn clockwise |
to “OFF”. |
Note: Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. DO NOT force.
4. | Open the fixed glass assembly. You may need to |
| remove the decorative front. |
5. | Wait five (5) minutes to clear out any gas. Then |
| smell for gas, including near the floor. If you smell |
| gas, STOP! Follow “B” in the Safety |
| Information located on the left side |
| of this label. If you don’t smell gas, |
| go to next step. |
6. | Find the pilot. The pilot is inside |
| combustion chamber next to the |
| main burner |
7. | Turn knob on gas control counterclockwise |
| to “PILOT”. |
8. | Push in control knob all the way and hold in. Immedi- |
WARNING: CAUTION:
ately depress red or black piezo button. It may require |
several depressions of the red or black piezo button |
until PILOT lights. If PILOT light does not light after |
10 seconds, return to step 3. Continue to hold the |
DO NOT CONNECT 110 VAC TO THE CONTROL VALVE.
Improper installation, adjustment, al- teration, service or maintenance can cause injury or property damage. Re- fer to the owner’s information manual provided with this appliance.
This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.
If not installed, operated, and main- tained in accordance with the man- ufacturer’s instructions, this product could expose you to substances in fuel or fuel combustion which are known to the State of California to cause can- cer, birth defects, or other reproductive harm.
Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.
Hot while in operation. DO NOT touch. Keep children, clothing, furniture, gaso- line and other liquids having flammable vapors away.
DO NOT operate the appliance with fixed glass assembly removed, cracked or broken. Replacement of the fixed glass assembly should be done by a licensed or qualified service person.
NOT FOR USE
WITH SOLID FUEL
For use with natural gas and propane. A conversion kit, as supplied by the manufacturer, shall be used to convert this appliance to the alternate fuel.
Also Certified for Installation in a Bedroom or a Bedsitting Room.
For assistance or additional informa- tion, consult a qualified installer, ser- vice agency or the gas supplier.
control knob in for about one minute after the pilot is |
lit. Release knob and it will pop back out. Pilot should |
remain lit. If it goes out, repeat steps 3 through 6. |
• If knob does not pop up when released, stop and |
immediately call your service technician or gas |
supplier. |
• If the pilot will not stay lit after several tries, turn |
the gas control knob to “OFF” and call your ser- |
vice technician or gas supplier. |
9. Reinstall fixed glass assembly. Reinstall decorative |
front. |
10. Turn gas control knob counterclockwise |
to “ON”. Close access panel. |
11. Turn on all electric power to the appliance. |
12. To light burner, turn the wall control or on/off switch |
to “ON”. |
TO TURN OFF
GAS TO APPLIANCE
1. | Turn off all electric power to the appliance if ser- |
| vice is to be performed. |
2. | Open control access panel. |
3. | Move switch to “OFF” position. |
For additional information on operating your
Hearth & Home Technologies fireplace, please refer to www.fireplaces.com.
Final inspection by
4. | Push in gas control knob slightly and turn clock- | |
| wise | to OFF”. DO NOT force. |
5. | Close control access panel. |
12 | Heat & Glo • |