BW36 SERIES WOODBURNING FIREPLACE

No one builds a better fire

12"

12"

MIN.

TOP OF

335/8"

FIREPLACE

 

OPENING

 

Figure 8a - Fireplace (Side View)

2.CHIMNEY HEIGHT REQUIREMENTS. (Above the roof line)

Major building codes specify a minimum chimney height above the roof top. These specifications are summarized in what is known as the “Ten Foot Rule”. This rule states: If the horizontal distance from the side of the chimney to the peak of the roof is 10 feet or less, the top of the chim- ney must be at least 2 feet above the peak of the roof, but never less than 3 feet in overall height above the highest point where it passes through the roof. See Figure 9.

If the horizontal distance from the side of the chimney to the peak of the roof is more than 10 feet, a chimney height reference point is established on the surface of the roof a distance of 10 feet from the side of the chimney in a horizontal plane. The top of the chimney must be at least 2 feet above this reference point, but never less than 3 feet in height above the highest point where it passes through the roof.

These chimney heights are necessary in the interest of safety and do not ensure smoke-free operation. Trees, buildings, adjoining roof lines, adverse wind conditions, etc., may create a need for a taller chimney should smok- ing occur.

DETERMINING THE NUMBER OF CHIMNEY SECTIONS REQUIRED.

To determine the chimney components needed to com- plete your particular installation, follow the below steps:

1.Determine the total vertical height of the fireplace installation. This dimension is measured from the base of the firebox assembly to the point where the smoke exits the terminal cap.

2.Subtract the height of the firebox assembly (3358") from the overall height of the fireplace installation.

3.Reference the below chart to determine what compo- nents must be selected to complete the fireplace installation.

4.Determine the number of firestop spacers, stabilizers, roof flashing, etc. required to complete the fireplace installation.

4-00

IF 10

FEET OR

LESS

THEN

MUST BE AT

LEAST 2 FEET

BUT

NEVER LESS

THAN 3 FEET

Figure 9

Chimney Height

Height of Chimney Components

Chimney Stabilizer

 

SL3

434

Firestop Spacers

 

FS338

0

FS339

0

FS340

0

Offset/Returns

 

SL315

1338

SL330

1412

Roof Flashing

 

RF370

0

RF371

0

 

 

Chimney Sections*

 

SL306

434

SL312

1034

SL318

1634

SL324

2234

SL336

3434

SL348

4634

 

 

*Dimensions reflect effective height.

13

30491D

Page 13
Image 13
Heat & Glo LifeStyle BW36 operating instructions Chimney Height REQUIREMENTS. Above the roof line