BW36 SERIES WOODBURNING FIREPLACE

No one builds a better fire

D.PRE-INSTALLATION PREPARATION

1.FIREPLACE LOCATIONS AND SPACE REQUIREMENTS.

Several options are available to you when choosing a location for your fireplace. This fireplace may be used as a room divider, installed along a wall, across a corner or use an exterior chase. See Figure 1.

As a room divider.

Along a wall.

In an exterior chase or projecting into a garage.

Across a corner.

Figure 1

Fireplace Locations

Figures 2 and 3 show two typical installations assuming an outside air kit is being used. Therefore, an allowance must be made for 90° bends. Less space is required when ducting goes directly outside without form- ing elbows.

193/4"

A

Figure 2

Installation along a wall or an exterior chase.

D

E D

C

A

B

Figure 3

Corner Installation

WITHOUT OUTSIDE AIR

 

WITH OUTSIDE AIR

 

 

 

 

 

 

 

 

 

 

 

 

CAT. #

A

 

 

 

CAT. #

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BW36

395/8"

 

 

 

BW36

395/8"

 

 

 

BW36C

395/8"

 

 

 

BW36C

395/8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WITH OR WITHOUT OUTSIDE AIR

 

 

 

 

 

 

 

 

 

CAT. #

A

B

C

D

E

 

 

 

 

 

 

 

 

 

 

BW36

395/8

621/4

31”

137/8

44”

 

 

 

 

 

 

 

 

 

 

BW36C

395/8

621/4

31”

137/8

44”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*A minimum of 1" air clearance must be maintained between the firebox and wall.

WARNING!

DO NOT DRAW OUTSIDE AIR FROM GARAGE SPACES. EXHAUST PRODUCTS OF GASOLINE ENGINES ARE HAZARDOUS.

DO NOT INSTALL OUTSIDE AIR DUCTS SUCH THAT THE AIR MAY BE DRAWN FROM ATTIC SPACES, BASEMENTS OR ABOVE THE ROOF WHERE OTHER HEATING APPLIANCES OR FANS AND CHIMNEYS EXHAUST OR UTILIZE AIR. THESE PRECAUTIONS WILL REDUCE THE POSSIBILITY FOR SMOKING OR FLOW REVERSAL.

4-00

8

30491D

Page 8
Image 8
Heat & Glo LifeStyle BW36 PRE-INSTALLATION Preparation, Fireplace Locations and Space Requirements, Cat. #