Heat & Glo LifeStyle Escape-42DVLP Top Vent - Vertical Termination, No Elbow, Two Elbows

Models: Escape-42DVLP Escape-42DV

1 61
Download 61 pages 27.53 Kb
Page 27
Image 27
Top Vent - Vertical Termination

Top Vent - Vertical Termination

No Elbow

Note: A fl ue restrictor can only be used in vent runs that in- clude no elbows and exceed 30 ft. total of straight vertical.

V1 = 50 ft. Max. (15.2 m)

V1 = 3 ft. Min. (914 mm)

FLUE

RESTRICTOR

FLUE No ElbowRESTRICTOR

V1

Figure 7.6

Two Elbows

Note: Must have a 24 inches mini- mum vertical vent before attaching any elbow to the unit.

Note: A fl ue restrictor can only be used in vent runs that in- clude no elbows and exceed 30 ft. total of straight vertical.

 

 

 

V1

 

H1

 

V2

 

 

2 ft.

 

610 mm

1 ft.

305 mm

 

*

 

 

3 ft.

 

914 mm

3 ft.

914 mm

 

*

 

 

4 ft.

 

 

1.2 m

4 ft.

1.2 m

 

*

 

 

 

 

 

 

 

 

 

 

 

 

5 ft.

 

 

1.5 m

9 ft.

2.7 m

 

*

 

 

6 ft.

 

 

1.8 m

12 ft.

3.7 m

 

*

 

 

 

 

V1 + V2 + H1 = 50 ft. (15.2 m) Max.

 

 

 

*No specifi c restrictions on this value EXCEPT

 

 

V1 + V2 + H1 cannot exceed 60 ft. (18.3 m).

 

V2

 

After V1 = 6 ft., then H1 Max.= V1 x 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H1

V1

Figure 7.7

Heat & Glo • Escape-42DV2052-900 Rev. Y • 11/11