Heat & Glo LifeStyle Escape-42DV IntelliFire Ignition System - continued, Symptom, Possible Cause

Models: Escape-42DVLP Escape-42DV

1 61
Download 61 pages 27.53 Kb
Page 54
Image 54

IntelliFire Ignition System - (continued)

Symptom

Possible Cause

Corrective Action

 

 

 

 

 

 

A. A shorted or loose connection in flame

Verify all connections to wiring diagram in manual. Verify

 

4. Pilot lights but contin-

sensing rod.

connections underneath pilot assembly are tight. Verify con-

 

ues to spark, and main

 

nections are not grounding out to metal chassis, pilot burn-

 

burner will not ignite.

 

er, pilot enclosure or screen if present, or any other metal

 

(If the pilot continues

 

object.

 

to spark after the

 

 

 

B. Poor fl ame rectifi cation or contaminated

With fi xed glass assembly in place, verify that fl ame is en-

 

pilot fl ame has been lit,

 

fl ame sensing rod.

gulfi ng fl ame sensing rod on left side of pilot hood. Flame

 

fl ame rectifi cation has

 

 

sensing rod should glow shortly after ignition. Verify cor-

 

not occurred.)

 

 

 

rect pilot orifi ce is installed and gas inlet is set to pressure

 

 

 

 

 

 

specifi cations. Clean fl ame sensing rod with emery cloth to

 

 

 

remove any contaminants that may have accumulated on

 

 

 

fl ame sensing rod.

 

 

 

 

 

 

C. Module is not grounded.

Verify module is securely grounded to metal chassis of ap-

 

 

 

pliance. Verify that wire harness is fi rmly connected to the

 

 

 

module.

 

 

 

 

 

 

D. Damaged pilot assembly or contami-

Verify that ceramic insulator around the fl ame sensing rod

 

 

nated fl ame sensing rod.

is not cracked, damaged, or loose. Verify connection from

 

 

fl ame sensing rod to white sensor wire. Polish fl ame sens-

 

 

 

 

 

ing rod with fi ne steel wool to remove any contaminants

 

 

 

that may have accumulated on fl ame sensing rod. Verify

 

 

 

continuity with a multimeter with ohms set at lowest range.

 

 

 

Replace pilot if any damage is detected.

 

 

 

 

 

 

E. Module.

Turn ON/OFF rocker switch or wall switch to OFF position.

 

 

 

Remove ignitor wire “I” from module. Place ON/OFF rocker

 

 

 

switch or wall switch in ON position. If there is no spark at “I”

 

 

 

terminal module must be replaced. If there is a spark at “I”

 

 

 

terminal, module is fi ne.

 

 

 

 

 

54

Heat & Glo • Escape-42DV2052-900 Rev. Y • 11/11

Page 54
Image 54
Heat & Glo LifeStyle Escape-42DV IntelliFire Ignition System - continued, Symptom, Possible Cause, Corrective Action