Heat & Glo LifeStyle SLR32 Top Vent - Horizontal Termination - continued, Venting with 2 elbows

Models: SLR32

1 70
Download 70 pages 24.45 Kb
Page 26
Image 26
1. Top Vent - Horizontal Termination - (continued)

1. Top Vent - Horizontal Termination - (continued)

Top Vent - Horizontal Termination

Venting with 2 elbows

 

V Minimum

H1 + H2 MAXIMUM

 

 

SLR32

 

 

 

 

 

90° Elbow

1 ft.

 

305 mm

 

 

 

 

 

 

1 ft.

 

305 mm

2 ft.

 

610 mm

 

 

 

 

 

 

2 ft.

 

610 mm

4 ft.

 

1.2 m

 

 

 

 

 

 

3 ft.

 

914 mm

6 ft.

 

1.8 m

 

 

 

 

 

 

4 ft.

 

1.2 m

15 ft.

 

4.6 m

 

 

 

 

 

 

H + H1 MAX. =15 ft. (4.6 m)

V + H + H1 MAX. = 40 ft. (12.2 m)

Note: Use SLP Series components only.

Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 7.3).

H2

H1

 

INSTALLED

HORIZONTALLY

Figure 7.5

V1

26

Heat & Glo • SLR32 • 2269-900 Rev. E • 4/12