0 Inches to 4 Inches Thick-Inside Fit Method

Non-Combustible Finish Materials

0 Inches to 4 Inches Thick-Inside Fit Method

The Tonic decorative front is approved for inside fit ap- plications. Non-combustible finishing materials up to 4 inches thick can be installed around the front (left, right, top, and bottom).

For the Tonic decorative front inside fit applications, the decorative front must be installed tight to the finishing flanges and must not overlap any finish material.

Ensure that minimum clearances to non-combustible fin- ish materials meet the specifications in Figure 13.11.

FACTORY-INSTALLED

NON-COMBUSTIBLE

BOARD

0-4 IN.

3/4 IN.

20-1/2 IN. APPLIANCE

OPENING (HEIGHT)

3 IN.

0- 4 IN.

DRYWALL OR

EQUIVALENT

(1/2 IN.)

Figure 13.10 Inside Fit Method (Tonic Decorative Front Only)

Non-Combustible Finish Material 0-4 Inches Thick

3/4 IN.

3/4 IN.

 

3 IN.

 

Bottom Joint

Figure 13.11 Noncombustible Surface Finishing Material 0-4 Inch

Thick-Inside Fit Method (Tonic Decorative Front

Only)