Top Vent - Horizontal Termination

1. Top Vent - Horizontal Termination - (continued)

 

 

 

 

 

 

Top Vent - Horizontal Termination

 

 

 

 

 

 

 

Venting with 3 elbows

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SLR32

 

 

 

V1 Minimum

H1 + H2 Maximum

V2

V1 + V2 Minimum

 

90° Elbow

6 ft.

 

 

 

1.8 m

*

*

 

1 ft.

305 mm

10 ft.

 

 

 

3.0 m

*

*

 

2 ft.

610 mm

12 ft.

 

 

 

3.7 m

*

*

 

3 ft.

914 mm

14 ft.

 

 

 

4.3 m

*

*

 

 

 

H1

+ H2

MAX. =14 ft. (4.3 m)

 

 

 

 

V1 + V2 + H1

+ H2 MAX. = 40 ft. (12.2 m)

 

 

*No specific restrictions on this value EXCEPT V1 + V2 + H cannot exceed 40 ft. (12.2 m)

 

Note: Use SLP Series components only.

Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 7.3).

H2

V2

H1

V1

Figure 7.6

Heat & Glo • SLR32 • 2269-900 Rev. E • 4/12