Heat & Glo LifeStyle SLR32 Venting with 4 elbows, Top Vent - Vertical Termination, V3 H2 H1 V1

Models: SLR32

1 70
Download 70 pages 24.45 Kb
Page 31
Image 31
Venting with 4 elbows

Top Vent - Vertical Termination

Venting with 4 elbows

Note: Use SLP Series components only.

Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 5.3).

V1 MIN.

 

H1 MAX.

V2 MIN.

H2 MAX.

V3 MIN.

 

 

 

 

 

 

 

 

 

 

1-1/2 ft.

457 mm

 

4 ft.

1.2 m

4 ft.

1.2 m

4 ft.

1.2 m

3-1/2 ft.

1.0 m

 

 

 

 

 

 

 

 

 

 

 

 

 

V1 + V2 + V3 + H1 + H2 Maximum= 40 ft. (12.2 m)

 

 

V3

V1 MIN.H1 MAX.H2

V2 MIN.H2 MAX.H1

V1

V2

Figure 7.12

Heat & Glo • SLR32 • 2269-900 Rev. E • 4/12