Heat & Glo LifeStyle ST-36TRB-IPI Top Vent - Horizontal Termination - continued, One Elbow

Models: ST-36TRB-IPI

1 82
Download 82 pages 9.56 Kb
Page 27
Image 27
1. Top Vent - Horizontal Termination - (continued)

1. Top Vent - Horizontal Termination - (continued)

One Elbow

H1

 

 

V1 Minimum

H1 Maximum

 

 

Elbow only

1-1/2 ft.

457 mm

 

 

6 in.

 

152 mm

2-1/2 ft.

610 mm

 

 

1 ft.

 

305 mm

3 ft.

914 mm

 

 

2 ft.

 

610 mm

6 ft

1.8 m

 

 

 

 

3 ft.

 

914 mm

9 ft.

2.7 m

 

 

4 ft.

 

1.2 m

12 ft.

3.7 m

V1

5 ft.

 

1.5 m

15 ft.

4.6 m

 

 

 

 

 

6 ft.

 

1.8 m

18 ft.

5.5 m

 

 

V1

+ H1 = 50 ft. (15.2 m) Maximum

 

 

 

H1 = 18 ft. (5.5 m) Maximum

Figure 7.4

Two Elbows

V1 Minimum

H1 + H2 Maximum

Elbow only

6 in.

152 mm

1 ft.

305 mm

2 ft.

610 mm

2 ft.

610 mm

4 ft.

1.2 m

3 ft.

914 mm

9 ft.

2.7 m

4 ft

1.2 m

12 ft.

3.7 m

5 ft.

1.5 m

15 ft.

4.6 m

6 ft.

1.8 m

18 ft.

5.5 m

V1 + H1 + H2 = 50 ft. (15.2 m) Maximum

H1 + H2 = 18 ft. (5.5 m) Maximum

H2

Figure 7.5

H1

INSTALLED

HORIZONTALLY

V1

Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI2128-900 Rev. H • 8/11

27

Page 27
Image 27
Heat & Glo LifeStyle ST-36TRB-IPI owner manual Top Vent - Horizontal Termination - continued, One Elbow, Two Elbows