G. Fixed Glass Assembly

G. Fixed Glass Assembly

WARNING! Risk of Asphyxiation! Handle fixed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches.

DO NOT strike, slam or scratch glass.

DO NOT operate fireplace with glass removed, cracked, broken or scratched.

Replace as a complete assembly.

Removing Fixed Glass Assembly

Pull the four glass latches out of the grooves on the glass frame top and bottom.

Remove the glass door from the appliance.

Multiple sides may be able to be removed based upon model.

Replacing Fixed Glass Assembly

Replace the glass door on the appliance.

Pull out the four glass latches and place in the grooves on the glass frame top and bottom.

Make sure all sides are replaced properly.

LATCHES

BOTH BOTTOM

AND TOP)

GLASS

ASSEMBLY

Figure 14.3 Fixed Glass Assembly

H. Install Trim Kits and Surrounds

Install optional trim kits and/or surrounds using the instructions included with the accessory.

Use non-combustible materials to cover the gap between the sheet rock and the appliance (when applicable to the model).

I. Air Shutter Setting

This appliance has an adjustable air shutter (which con- trols the primary air) factory set for the minimum vertical vent run (see Figure 12.15). If your installation has more than the minimum required vertical vent length, adjust- ment of the air shutter may be necessary to obtain opti- mal flame appearance. This should be adjusted by a qualified installer at the time of installation.

By pushing the air shutter handle towards the pilot, you will be closing the air shutter. To adjust loosen the wing nut. Care should be taken when adjusting the air shutter so as not to cause the appliance to soot. If sooting occurs the air shutter will need to be opened by pushing the handle away from the pilot. When finished tighten wing nut.

NOTICE: If sooting occurs, provide more air by opening the air shutter.

AIR SHUTTER

OPEN

CLOSED

Figure 14.4 Air Shutter

Air Shutter Settings

 

NG

LP

Burner

1/8 in.

Fully open

Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI2128-900 Rev. H • 8/11