Heat & Glo LifeStyle ST-36TRB-IPI B. Vent Components Diagrams continued, Slp-Snkd, Slp-Ccs-Bk

Models: ST-36TRB-IPI

1 82
Download 82 pages 9.56 Kb
Page 75
Image 75
SLP-SNKD

B. Vent Components Diagrams (continued)

Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B will be required.

SLP-CCS-BK 8 in.DVP-FBHT (203 mm)

Heat

Shield

15-1/8 in.

(384 mm)

 

Max

12 in.

Effective

(305 mm)

Length

SLP-TRAP

Horizontal Termination Cap

Term Cap

Minimum

Maximum

Effective Length

Effective Length

 

Trap1

3-1/8 in.

4-3/4 in.

79 mm

121 mm

 

Trap2

5-1/4 in.

9-1/4 in.

133 mm

235 mm

 

SLP-SNKD

SLP-CCS-BK

SLP-TVHW

 

DVP-FBHT

Cathedral Ceiling

Vertical

 

Horizontal

Snorkel

 

Support Box-Black

Termination Cap

Termination Cap

Termination Cap

 

 

 

 

 

 

 

 

26 in.

 

 

 

 

660 mm

 

SL-2DVP

DVP-2SL

 

DVP-HSM-B

 

Adapter

Adapter

Extended Heat Shield

SLP-DCF-BK

SLP-WT-BK

Ceiling Firestop

Wall Thimble-Black

Black

 

Figure 16.10 SLP Series Vent Components

Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI2128-900 Rev. H • 8/11

75

Page 75
Image 75
Heat & Glo LifeStyle ST-36TRB-IPI B. Vent Components Diagrams continued, Slp-Snkd, Slp-Ccs-Bk, Dvp-Fbht, Horizontal