AIR PURGING

Air purging

Air and moisture remaining in the refrigerant system have undesirable effects as indicated below.

Pressure in the system rises.

Operating current rises.

Cooling(or heating) efficiency drops.

Moisture in the refrigerant circuit may freeze and block capillary tubing.

Water may lead to corrosion of parts in the

refrigeration system.

Therefore, the indoor unit and tubing between the indoor and outdoor unit must be leak tested and evacuated to remove any noncondensables and moisture from the system.

Air purging with vacuum pump

APreparation

Check that each tube(both liquid and gas side tubes) between the indoor and outdoor units have been properly connected and all wiring for the test run has been completed. Remove the service valve caps from both the gas and the liquid side on the outdoor unit. Note that both the liquid and the gas side service valves on the outdoor unit are kept closed at this stage.

BLeak test

Connect the manifold valve(with pressure gauges) and dry nitrogen gas cylinder to this service port with charge hoses.

CAUTION

Be sure to use a manifold valve for air purging. If it is not available, use a stop valve for this purpose. The "Hi" knob of the manifold valve must always be kept close.

Pressurize the system to no more than 150 P.S.I.G. with dry nitrogen gas and close the cylinder valve when the gauge reading reached 150 P.S.I.G. Next, test for leaks with liquid soap.

CAUTION

To avoid nitrogen entering the refrigerant system in a liquid state, the top of the cylinder must be higher than its bottom when you pressurize the system. Usually, the cylinder is used in a vertical standing position.

17

Do a leak test of all joints of the tubing(both indoor and outdoor) and both gas and liquid side service valves.

Bubbles indicate a leak. Be sure to wipe off the soap with a clean cloth.

After the system is found to be free of leaks, relieve the nitrogen pressure by loosening the charge hose connector at the nitrogen cylinder. When the system pressure is reduced to normal, disconnect the hose from the cylinder.

Indoor unit

Outdoor unit

Manifold valve

Pressure

Lo Hi

gauge

 

Charge hose

Nitrogen gas cylinder(in vertical standing position)

Page 17
Image 17
Heat Controller HMH30AS-1, HMC30BS-1, HMC30AS-1 manual AIR Purging, Air purging with vacuum pump, Preparation, Leak test

HMC30AS-1, HMH30BS-1SINGLE-ZONE, HMH30AS-1, HMC30BS-1 specifications

The Heat Controller HMC30AS-1, HMH30AS-1, HMH30BS-1 SINGLE-ZONE, and HMC30BS-1 are cutting-edge HVAC systems designed to provide optimal comfort and efficiency in both residential and commercial settings. These models embody the latest advancements in heating and cooling technology, making them ideal choices for anyone looking to enhance their indoor environment.

One of the standout features of these heat controllers is their energy efficiency. With advanced inverter technology, these products adjust compressor speed based on the heating or cooling demand, significantly reducing energy consumption compared to traditional systems. This not only lowers utility bills but also reduces environmental impact, making them a sustainable choice for eco-conscious consumers.

The HMC30AS-1, HMH30AS-1, HMH30BS-1 SINGLE-ZONE, and HMC30BS-1 also come with programmable thermostats, allowing users to set specific temperature schedules according to their daily routines. This convenience ensures that spaces are always at the desired temperature when occupied, providing a perfect balance between comfort and energy conservation.

Another impressive characteristic is their quiet operation. These systems are engineered with sound-dampening technology, minimizing noise levels and ensuring a peaceful indoor atmosphere. This is especially beneficial for bedrooms, offices, or any spaces where tranquility is essential.

Durability and reliability are also hallmarks of these models. Built with high-quality materials and robust components, they are designed to withstand varying environmental conditions while providing consistent performance. The heat controllers also come with comprehensive warranties, giving users added peace of mind regarding their investment.

In addition to their efficiency and durability, these systems offer versatile installation options. Whether it's a compact single-zone setup or a larger installation, the HMC30 series is adaptable, making it suitable for various building layouts.

With their modern design and user-friendly interfaces, these heat controllers blend seamlessly into contemporary spaces. Smart technology options enable integration with mobile apps and smart home systems, allowing for remote monitoring and adjustment.

From energy-saving features to quiet operation, the Heat Controller HMC30AS-1, HMH30AS-1, HMH30BS-1 SINGLE-ZONE, and HMC30BS-1 represent the pinnacle of heating and cooling solutions, meeting the diverse needs of today's consumers.