INSTALLATION OF INDOOR, OUTDOOR UNIT

INSTALLATION OF INDOOR, OUTDOOR UNIT

Read completely, then follow step by step.

Select the best location

A Indoor unit

Do not have any heat or steam near the unit.

Select a place where there are no obstacles in front of the unit.

Make sure that condensation drainage can be conveniently routed away.

Do not install near a doorway.

Ensure that the space around the left and right of the unit is more than 30cm(11.8in). The unit should be installed as high on the wall as possible, allowing a minimum of 12cm(4.7in) from ceiling.

Use a stud finder to locate studs to prevent unnecessary damage to the wall.

 

More than

More than

12cm(4.7in)

 

30cm(11.8in)

 

 

More than

 

30cm(11.8in)

More than 2.3m(7.6ft)

 

CAUTION

Install the indoor unit on the wall where the height from the floors more than 2.3meters(7.6ft).

A minimum pipe run of 7.5meters(24.6ft) is required to minimize vibration & excessive noise.

Rooftop Installations:

If the outdoor unit is installed on a roof structure, be sure to level the unit. Ensure the roof structure and anchoring method are adequate for the unit location. Consult local codes regarding rooftop mounting.

If the outdoor unit is installed on root structures or walls, this may result in excessive noise and vibration, and maybe also classed as non serviceable installation.

Piping length and elevation

Capacity

 

Pipe Size

Standard

 

Max.

Max.

Additional

 

 

 

Length

Elevation

length

Refrigerant

(Btu/h)

 

Suction

Evap

m(ft)

 

B m(ft)

A m(ft)

g/m(oz/ft)

 

 

 

 

 

 

 

 

 

 

 

30k

 

5/8"

3/8"

7.5(25)

15(49)

30(98)

30(0.32)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor unit

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor unit

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

Outdoor unit

If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not restricted.

Ensure that the space around the back and sides is more than 10cm(3.9in). The front of the unit should have more than 70cm(27.6in) of space.

Do not place animals and plants in the path of the warm air.

Take the air conditioner weight into account and select a place where noise and vibration are minimum.

Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.

More than 60cm(23.6in)

More than

More than

Outdoor unit

Oil trap

A

 

Indoor unit

 

B

In case more than 5m(16.4ft)

CAUTION

Capacity is based on standard length and maximum allowance length is on the basis of reliability.

Oil trap should be installed every 5~7meters (16.4~23.0ft).

10cm(3.9in)

10cm(3.9in)

More than

More than

70cm(27.6in)

60cm(23.6in)

 

4