TEST RUNNING

1.Check that all tubing and wiring have been properly connected.

2.Check that the gas and liquid side service valves are fully open.

APrepare remote control

Remove the battery cover by pulling it according to the arrow direction.

Insert new batteries making sure that the (+) and (–) of battery are installed correctly.

Reattach the cover by pushing it back into position.

NOTE:

Use 2 AAA(1.5volt) batteries. Do not use rechargeable batteries.

Remove the batteries from the remote control if the system is not going to be used for a long time.

BSettlement of outdoor unit

Anchor the outdoor unit with a bolt and

nut(ø 10mm(0.39in) tightly and horizontally on a concrete or rigid mount.

When installing on the wall, roof or rooftop, anchor the mounting base securely with a nail or wire assuming the influence of wind and earthquake.

In the case when the vibration of the unit is conveyed to the hose, secure the unit with an anti-vibration rubber.

Bolt

Tubing connection

CEvaluation of the performance

Operate unit for 15~20 minutes, then check the system refrigerant charge:

1.Measure the pressure of the gas side service valve.

2.Measure the temperature of the intake and discharge of air.

3.Ensure the difference between the intake temperature and the discharge is more than 8°C(46.4°F) (Cooling) or reversely (Heating).

Intake temperature

Discharge air

Discharge temperature

4.For reference; the gas side pressure of optimum condition is as below.(Cooling)

Outside ambient TEMP.

The pressure of the gas side service valve

 

 

35°C(95°F)

4~5kg/cm2 G(56.8~71.0 P.S.I.G.)

NOTE: If the actual pressure are higher than shown, the system is most likely over-charged, and charge should be removed. If the actual pressure are lower than shown, the system is most likely undercharged, and charge should be added.

The air conditioner is now ready for use.

PUMP DOWN

This is performed when the unit is to be relocated or the refrigerant circuit is serviced.

Pump Down means collecting all refrigerant in the outdoor unit without loss in refrigerant gas.

CAUTION:

Be sure to perform Pump Down procedure with the unit cooling mode.

Pump Down Procedure

1.Connect a low-pressure gauge manifold hose to the charge port on the gas side service valve.

2.Open the gas side service valve halfway and purge the air from the manifold hose using the refrigerant gas.

3.Close the liquid side service valve(all the way in).

4.Turn on the unit's operating switch and start the cooling operation.

5.When the low-pressure gauge reading becomes 1 to 0.5kg/cm2 G(14.2 to 7.1 P.S.I.G.), fully close the gas side valve stem and then quickly turn off the unit. At that time, Pump Down has been completed and all refrigerant gas will have been collected in the outdoor unit.

20

Page 20
Image 20
Heat Controller HMC30BS-1 Test Running, Prepare remote control, Settlement of outdoor unit, Evaluation of the performance

HMC30AS-1, HMH30BS-1SINGLE-ZONE, HMH30AS-1, HMC30BS-1 specifications

The Heat Controller HMC30AS-1, HMH30AS-1, HMH30BS-1 SINGLE-ZONE, and HMC30BS-1 are cutting-edge HVAC systems designed to provide optimal comfort and efficiency in both residential and commercial settings. These models embody the latest advancements in heating and cooling technology, making them ideal choices for anyone looking to enhance their indoor environment.

One of the standout features of these heat controllers is their energy efficiency. With advanced inverter technology, these products adjust compressor speed based on the heating or cooling demand, significantly reducing energy consumption compared to traditional systems. This not only lowers utility bills but also reduces environmental impact, making them a sustainable choice for eco-conscious consumers.

The HMC30AS-1, HMH30AS-1, HMH30BS-1 SINGLE-ZONE, and HMC30BS-1 also come with programmable thermostats, allowing users to set specific temperature schedules according to their daily routines. This convenience ensures that spaces are always at the desired temperature when occupied, providing a perfect balance between comfort and energy conservation.

Another impressive characteristic is their quiet operation. These systems are engineered with sound-dampening technology, minimizing noise levels and ensuring a peaceful indoor atmosphere. This is especially beneficial for bedrooms, offices, or any spaces where tranquility is essential.

Durability and reliability are also hallmarks of these models. Built with high-quality materials and robust components, they are designed to withstand varying environmental conditions while providing consistent performance. The heat controllers also come with comprehensive warranties, giving users added peace of mind regarding their investment.

In addition to their efficiency and durability, these systems offer versatile installation options. Whether it's a compact single-zone setup or a larger installation, the HMC30 series is adaptable, making it suitable for various building layouts.

With their modern design and user-friendly interfaces, these heat controllers blend seamlessly into contemporary spaces. Smart technology options enable integration with mobile apps and smart home systems, allowing for remote monitoring and adjustment.

From energy-saving features to quiet operation, the Heat Controller HMC30AS-1, HMH30AS-1, HMH30BS-1 SINGLE-ZONE, and HMC30BS-1 represent the pinnacle of heating and cooling solutions, meeting the diverse needs of today's consumers.