Final stage:

The final stage of burning is the charcoal stage. This occurs when the flammable gases have been mostly burned and only charcoal remains. This is a naturally clean portion of the burn. The coals burn with hot blue flames.

It is very important to reload your fireplace while enough lively hot coals remain in order to provide the amount of heat needed to dry and rekindle the next load of wood. It is best to open the air control for a short while before reloading. This livens up the coalbed. Open door slowly so that ash or smoke does not exit fireplace through opening. You should also break up any large chunks and distribute the coals so that the new wood is laid evenly on hot coals.

Fireplace operation does require air. Do not take air from other fuel burning appliances which can result in improper venting (smoking) or air dilution. Always provide adequate makeup air.

O. Automatic Combustion Control (ACC)

IMPORTANT! As you move the Combustion Air Control to the RIGHT, you will feel resistance about three-fourths of the way. You must move past that resistance approxi- mately 3/4 in. (19mm) to fully engage the Automatic Combustion Control (ACC) sytstem.

With the Automatic Combustion Control system that is on this fireplace, you can set the fireplace to high (slide the Combus- tion Air Control all the way to the right), start the fire, and then move the Combustion Air Control to the desired burn level. The fireplace will automatically go to that level once the fire is fully established. This allows for less interaction with the fire by the homeowner and more efficient use of fuel while maintaining the desired heat output.

After the fireplace has been in operation for a period of time, and is warmed up; you may prefer to not activate the ACC when reloading fuel. if you do not slide the Combustion Air Control all the way to the right, the ACC will not be activated.

ACC OVERRIDE

The lever located to the left of the Combustion Air Control is the ACC OVERRIDE and may be used to override the setting of the Combustion Air Control. If the ACC has been activated and burn rate needs to be slowed, move the lever to the LEFT and position Combustion Air Control at the preferred setting. To close the air supply for an over fire situatution or to slow the burn rate down immediately, slide the lever to the LEFT and also slide the Combustion Air Control all the way to the left.

NOTICE: If reloading a bright, hot coal bed for longer (low) burn time, setting the ACC may not be required. Burn Dry, well seasoned wood.

NOTICE: To establish your settings, always begin with the air control all the way to the left to STOP and then move it to the right for your desired setting.

Left-Close

Right-Open

 

 

Low

Meet

ACC Fully

 

Position

Resistance

Engaged

Figure 2.5 Operating the ACC Controls

 

*Slide Air Control Slide LEFT to Stop

Stop to 1/8 in. -1/2 in. open

Stop to 1/2 in. - 1-1/2 in. open

All the way to RIGHT

Notice:

THE DECORATIVE FASCIA MUST BE REMOVABLE ON YOUR FIREPLACE IN ORDER TO SERVICE THE AUTO- MATIC COMBUSTION CONTROL SYSTEM.

4/20/11

Heatilator • Constitution EPA Fireplace • 480-1091D

Page 15

Page 15
Image 15
Heatiator C40 owner manual Automatic Combustion Control ACC, Final stage, Slide Air Control Slide Left to Stop

C40 specifications

The Heatiator C40 is an innovative heating solution designed to optimize comfort and energy efficiency in residential and commercial spaces. This advanced heating unit combines modern technology with user-friendly features, making it an excellent choice for anyone looking to improve their heating systems.

One of the standout features of the Heatiator C40 is its powerful heating capacity. With an output of up to 40,000 BTUs, this unit is capable of efficiently warming large areas, ensuring that no space is left cold. The C40 utilizes high-efficiency burners that maximize heat output while minimizing fuel consumption. This not only translates to lower energy bills for the consumer but also contributes to a reduced carbon footprint.

The Heatiator C40 is equipped with advanced smart technology, allowing users to control their heating environment remotely. With the Heatiator mobile app, users can adjust the temperature settings, set schedules, and monitor energy usage from their smartphones. This level of control ensures that comfort is maintained without unnecessary energy waste.

Another notable characteristic of the C40 is its versatile design. The unit can be easily installed in various configurations, including wall-mounted, freestanding, or built-in options, making it suitable for any room layout or decor. Its sleek, compact design also ensures that it blends seamlessly into any environment, providing users with both functionality and aesthetic appeal.

Safety is a priority in the design of the Heatiator C40. The unit is equipped with multiple safety features, including overheat protection, a flame failure device, and an automatic shut-off system. These safety measures provide peace of mind, allowing users to enjoy their heating without worry.

Furthermore, the Heatiator C40 operates quietly, making it an ideal choice for bedrooms and living areas where noise can be a distraction. The noise-reduction technology incorporated into the unit ensures that the heating process is unobtrusive, allowing for a peaceful environment.

In summary, the Heatiator C40 is a cutting-edge heating solution that stands out due to its powerful performance, energy efficiency, and user-friendly technology. With its stylish design, safety features, and advanced controls, the C40 is an excellent investment for anyone looking to enhance their heating system while enjoying the comfort of a warm, inviting space. Whether for homes or businesses, the Heatiator C40 promises reliable performance and satisfaction.