Heatiator owner manual GC150 SERIES DIRECT VENT GAS APPLIANCE, Wiring, Lower Panel Removal

Models: GC150

1 28
Download 28 pages 32.15 Kb
Page 14
Image 14
STEP 6 - Lower Panel Removal

GC150 SERIES DIRECT VENT GAS APPLIANCE

STEP 6 - Lower Panel Removal

To remove the lower panel, gently lift and pull on the out- side edges of the panel as shown in Figure 18.

To replace the panel, reverse this action.

Figure 18

Lower Panel Removal

STEP 7 - Wiring

A. ELECTRONIC IGNITION

1.Appliance Requirements. This appliance requires a 110VAC supply from a wall switch to the appliance junction box for opera- tion. A wiring diagram is shown in Figure 19.

2.Optional Accessories Requirements. Wiring for optional accessories should be done now to avoid reconstruction.

Note: This appliance must be electrically wired and grounded in accordance with local Codes or, in the absence of local Codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code, CSA C22.1.

14-3 with ground Romex is the recommended wiring to the appliance Junction Box. This allows each outlet to power the unit and fan independently.

Detailed Picture of Junction Box

Figure 19

Electronic Ignition Wiring Diagram

4-99

14

21322M

Page 14
Image 14
Heatiator GC150 SERIES DIRECT VENT GAS APPLIANCE, Wiring, Figure Lower Panel Removal, A. Electronic Ignition