![STEP 6 - Lower Panel Removal](/images/new-backgrounds/43405/4340527x1.webp)
GC150 SERIES DIRECT VENT GAS APPLIANCE
STEP 6 - Lower Panel Removal
To remove the lower panel, gently lift and pull on the out- side edges of the panel as shown in Figure 18.
To replace the panel, reverse this action.
Figure 18
Lower Panel Removal
STEP 7 - Wiring
A. ELECTRONIC IGNITION
1.Appliance Requirements. This appliance requires a 110VAC supply from a wall switch to the appliance junction box for opera- tion. A wiring diagram is shown in Figure 19.
2.Optional Accessories Requirements. Wiring for optional accessories should be done now to avoid reconstruction.
Note: This appliance must be electrically wired and grounded in accordance with local Codes or, in the absence of local Codes, with National Electric Code ANSI/NFPA
Detailed Picture of Junction Box
Figure 19
Electronic Ignition Wiring Diagram
14 | 21322M |