Heatiator GC150 SERIES DIRECT VENT GAS APPLIANCE, Do Not Hit, Strike Or Slam Shut The Glass

Models: GC150

1 28
Download 28 pages 32.15 Kb
Page 18
Image 18
Figure 29 - Placing the Lava Rock and Vermiculite

GC150 SERIES DIRECT VENT GAS APPLIANCE

Figure 29 - Placing the Lava Rock and Vermiculite

STEP 13 - Placing the Lava Rock, Vermiculite and Rock Wool

Spread the lava rock over the area in front of the burner and the two side pans. Do not cover the front gas ports with the lava rock. See Figure 29.

Take a small amount of vermiculite and sprinkle it on top of the lava rock. Do not cover the front gas ports with the vermiculite. See Figure 29.

Break the rock wool into pieces, no bigger than 1/2" diameter, and place them close to the front gas ports so that the flame can touch the rock wool. This cre- ates the glowing ember look. Be sure not to pack the rock wool against the gas ports. See Figure 30.

When the unit is lit and the front gas ports will not light, make sure that the ports are not block by lava rock or vermiculite.

Note: The placement of the logs, lava rock, vermi- culite and rock wool is very critical to the appear- ance of the fireplace looks during its operation. Please take time during this portion of the setup to achieve the best appearance.

STEP 14 - Glass Replacement

After arranging the log set in the unit, replace the fixed pane of glass. Be sure the rubber gasket mate- rial is on the top and bottom edges of the glass. Carefully lower the glass into the lower track of the unit (black trim facing outward) and center it in the track. Next, place the metal retaining strip along the upper edge of the glass and align the screw holes with holes in the fireplace. Secure the glass into place with the provided screws. See Figure 31.

WARNING!

NEVER OPERATE THIS APPLIANCE WITH THE GLASS REMOVED OR NOT SEALED.

WARNING!

DO NOT HIT, STRIKE OR SLAM SHUT THE

GLASS.

Figure 30

Placing the Rock Wool

Figure 31

Glass Replacement

STEP 16 - Screen Replacement

Position the screen over the glass, align the screw holes located in each upper corner of the panel with the holes in the fireplace and screw into place.

STEP 17 - Replacing the Panels

Simply replace each panel by positioning the notch- es, located on each end of the panel, in place over the pins on either side of the panel opening and press downward. The panel should snap into place easily. See Figure 32.

Figure 32

Lower Panel Replacement

12-98

18

21322K

Page 18
Image 18
Heatiator GC150 SERIES DIRECT VENT GAS APPLIANCE, Do Not Hit, Strike Or Slam Shut The Glass, Glass Replacement