Heatiator owner manual Viii. Trouble Shooting, ELECTRONIC IGNITION GC150E

Models: GC150

1 28
Download 28 pages 32.15 Kb
Page 25
Image 25
VIII. TROUBLE SHOOTING

GC150 SERIES DIRECT VENT GAS APPLIANCE

VIII. TROUBLE SHOOTING

ELECTRONIC IGNITION (GC150E)

Problem

1.Spark ignitor will not light burner after repeated attempts.

2.Burner will not stay lit.

3.With valve and wall switch in “ON” position, no gas to burner.

4.Glass doors fog up.

5.Blue flames.

Cause

A.Defective ignitor; loose wire.

B.Misaligned electrode at ignitor.

A.Defective ignitor.

B.No ground.

A. Manual on/off valve(s) shut off.

B.Plugged burner orifice.

C.Wall switch defective.

D.No Power

A.A normal result of gas combustion.

A.A normal result during the first 20 minutes of burning.

Corrective Action

Check for loose connections on electrode and ignitor. Refer to the wiring diagram on page 13 for assistance.

Check for spark. If electrode connection is correct and there is no spark, replace ignitor.

Spark should be extending approx. 3/16" to ground wire. See Figure 42. Adjust gap to give proper spark. Remove hands from electrode before attempting.

Check burner flame. See Figure 41. Adjust ignitor if neces- sary.

Be sure ignitor is secured tight into bracket and bracket is secured tightly to the unit.

Be sure wiring connections are tight throughout system, including high limit switch.

Check that wiring is grounded as shown in Figure 19.

Check all gas valves leading to appliance. Turn to the “ON” position. Check for 24 volt power off secondary on the trans- former.

Check burner orifice; remove blockage.

Check continuity.

Check 110VAC supply (Fuses/Breaker)

No action is necessary. After the fireplace has warmed up, the glass will clear.

No action is necessary. Flames will begin to turn more yel- lowish after about 20 minutes of burning. If blue flames per- sist, check air shutter setting and check log and embers are positioned correctly.

B. Improper air mixture.

Check air shutter setting.

4-99

25

21322M

Page 25
Image 25
Heatiator owner manual Viii. Trouble Shooting, ELECTRONIC IGNITION GC150E, GC150 SERIES DIRECT VENT GAS APPLIANCE