I. LISTINGS AND CODE APPROVALS

GC150 SERIES DIRECT VENT GAS APPLIANCE

I. LISTINGS AND CODE APPROVALS

Certification

The GC150 Series Vented Gas Fireplace has been tested in accordance with the ANSI standard ANSI Z21.50-1998lCGA 2.22-M98 and has been listed by Warnock Hersey for installation and operation as described in these Installation and Operating Instructions. All components are A.G.A. or UL safety certified.

Local codes

Check with your local building code agency prior to in- stalling this appliance to ensure compliance with local codes, including the need for permits and follow-up inspections. This installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-latest edition, in the U.S.A. and the CAN/CGA B149, Installation Codes, in Canada.

A manufactured home installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSI Z225.1/NFPA 501A.

Optional components

This gas appliance has been tested and listed for use

with the optional components listed on page 4. Many optional components may be purchased separately and installed at a later date. However, installation of a remote control or fan kit will require electrical power. To avoid costly reconstruction, electrical power should be connected to the unit at the time of the initial fire- place installation for possible addition of these acces- sories at a later date.

Fuel

Any additions, changes or conversions required in order for the appliance to satisfactorily meet the appli- cation needs must be made by a Heatilator distributor using factory specified and approved parts.

This product is manufactured to use natural gas and is available in propane gas. In the event your appli- ance must be converted to either natural gas from propane or to propane gas from natural you must use a proper conversion kit.

If any assistance is required during installation please contact your local dealer or contact Heatilator Technical Services Department, 1915 W. Saunders Street, Mt. Pleasant, Iowa 52641.

HEATILATOR® is a registered trademark of Heatilator, a Division of Hearth Technologies Inc.

II. DESCRIPTION OF THE FIREPLACE SYSTEM

The GC150 is a vented gas fireplace. Combustion air is supplied from outside, not from inside the house as with other types of fireplaces. While a significant amount of heat is created by the GC150, it is not intended to be and, therefore, should not be used as a heater.

This HEATILATOR fireplace system consists of the following:

1.Fireplace

2.Venting System

3.Termination

Optional components include:

1.Trim kits

2.Fan kit

3.Remote control

Note: Illustrations throughout these instructions reflect typical installations and are for design pur- poses only. Actual installation may vary slightly due to individual design preferences. However, mini- mum and maximum clearances must be maintained at all times.

The illustrations and diagrams used throughout these installation instructions are not drawn to scale.

Tools and building supplies normal- ly required for installation:

Tools:

Building Supplies:

Saw

Wall-finishing materials

Pliers

Framing material

Hammer

Fireplace surround

Phillips screwdriver

High Temp. Caulking

Tape measure

Material (300° F+)

Plumb line

 

Level

 

Drill and Bits

 

Square

 

Note: Operation of a direct vent fireplace may be sporadic in high wind situations.