| GC150 SERIES DIRECT VENT GAS APPLIANCE | |
| Table of Contents |
|
I. | Listings and Code Approvals | 3 |
II. | Description of the Fireplace System | 3 |
III. Fireplaces System Components and Dimensions | 4 | |
IV. | 6 | |
| A. Gas Pressure | 6 |
| B. High Altitude Installation | 6 |
| C. Fireplace Locations and Space Requirements | 6 |
| D. Clearances | 6 |
| E. Framing The Fireplace | 7 |
| F. Finishing Materials | 7 |
V. | 8 | |
| A. Horizontal Termination | 8 |
| B. Vertical Termination | 11 |
VI. | Operating Instructions | 19 |
| A. Standing Pilot Operation | 22 |
| B. Electronic Ignition Operation | 23 |
VII. | Maintenance Instructions | 24 |
VIII. | Trouble Shooting | 25 |
IX. | Replacement Parts | 27 |
| Safety Precautions |
|
1.Please read these installation instructions complete- ly before beginning installation procedures. Failure to follow them could cause a fireplace malfunction resulting in serious injury and/or property damage.
2.Always check your local building codes prior to installation. This installation must comply with all local, regional, state and national codes and regula- tions.
3.Installation and repair should be done by a qualified service person. This appliance should also be inspected annually by a qualified service person. More frequent inspections/cleaning may be required due to excessive lint from carpeting, bedding materi- al, etc. It is imperative that the control compartment, burners and circulating air passage ways of the appliance be kept clean.
4.The GC150 fireplace is a vented gas fireplace. Do not burn wood or other material in this appliance.
5.NEVER leave children unattended when there is a fire burning in the fireplace.
6.This fireplace may be vented horizontally through an outside wall or vertically above the roof line and must not be connected to a chimney flue servicing a solid fuel burning appliance.
7.NEVER use gasoline,
8.While servicing this fireplace, always shut off all electricity and gas to the fireplace. This will prevent possible electrical shock or burns. Also, make sure
the unit is completely cooled before servicing.
9.During any pressure testing of the gas supply piping system that exceeds test pressures of 1/2 psig, this appliance and its individual
10.Do not use this appliance if any part has been under water. Immediately call a qualified service techni- cian to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
11.Be sure to provide adequate clearances around the air openings into the combustion chamber and ade- quate accessibility clearances for servicing and proper operation.
12.The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
13.Provisions shall be made to provide adequate combustion and ventilation air.
14.The appliance area shall be kept clear and free from combustible materials, gasoline and other flammable vapors and liquids.
15.The flow of combustion and ventilation air should not be obstructed.
2 | 21322L |