Heatiator NNXT4236I H. IPI Battery Tray/Battery Installation, I. Control Module Operation

Models: NNXT4236I NNXT4236IL NNXT3933I NNXT3933IL

1 82
Download 82 pages 55.73 Kb
Page 11
Image 11

H. IPI Battery Tray/Battery Installation

The IntelliFire PlusTM system has a battery backup option. Battery longevity and performance will be affected by the service temperatures of this appliance.

NOTICE: Batteries should only be used as a power source in the event of an emergency such as an outage.

I. Control Module Operation

1.The control module has an ON/OFF/REMOTE selector switch that must be set. See Figure 2.3.

OFF Position: Appliance will ignore all power inputs and will not respond to any commands from a wall switch or remote. The unit should be in the OFF position during installation, service, battery installation, fuel conversion, and in the event that the control goes into LOCK-OUT mode as a result of an error code.

ON Position: Appliance will ignite and run continuously in the HI flame setting, with no adjustment in flame output. This mode of operation is primarily used for initial installation or power outage operation with battery backup.

REMOTE Position: Appliance will initiate commands from an optional wired wall switch and/or the wireless remote.

2.If using a wired wall switch with the module in REMOTE mode, the flame output can be adjusted with the HI/LO selector switch on the module. See Figure 2.3. Note that the flame HI/LO selector switch will become inactive once an optional remote control is programmed to the control module. Note that the control module will always ignite the fireplace on HI and remain so for the initial 10 seconds of operation. If the HI/LO is switched to the LO position, the flame output will automatically drop to the lowest setting after the flame has been established for 10 sec. After this 10 second period, the flame can be adjusted from HI to LO with the switch.

3.The control module has safety feature that automatically shuts down the fireplace after 9 hours of continuous operation without receiving a command from the remote.

4.If you intend to use both an optional wired wall switch and the remote control to operate your fireplace, the wall switch will override any commands given by the remote.

5.Module Reset

This module may lock-out under certain conditions. When this occurs, the appliance will not ignite or respond to commands. The module will go into lock-out mode by emitting three audible beeps, then continuously displaying a RED/GREEN error code at its status indicator LED.

Check battery tray. Remove batteries if installed. Batteries should only be installed for use during power outages. See Section H.

Locate the module selector switch. (See Figure 2.3).

Set the module selector switch to the OFF position.

 

MODULE

 

NG/LP SETTING

WIRE LEAD FROM REGULATOR CONNECTS HERE

Figure 2.3

Control Module

Wait five (5) minutes to allow possible accumulated gas to clear.

Set the module selector switch to ON or REMOTE position.

Start the appliance.

WARNING! Risk of Explosion! DO NOT press the mod- ule reset switch more than one time within a five minute time period. Gas may accumulate in firebox. Call a quali- fied service technician.

Nine Hour Safety Shutdown Feature

This appliance has a safety feature that automatically shuts down the fireplace after 9 hours of continuous operation without receiving a command from the remote.

J. Before Lighting Fireplace

Before operating this fireplace for the first time, have a qualified service technician:

Verify all shipping materials have been removed from inside and/or underneath the firebox.

Review proper placement of logs, rockwool and/or other decorative materials.

Check the wiring.

Check the air shutter adjustment.

Ensure that there are no gas leaks.

Ensure that the glass is sealed and in the proper position and that the integral barrier is in place.

WARNING! Risk of Fire or Asphyxiation! DO NOT oper-

ate fireplace with fixed glass assembly removed.

Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12

11

Page 11
Image 11
Heatiator NNXT4236I H. IPI Battery Tray/Battery Installation, I. Control Module Operation, J. Before Lighting Fireplace