5 Framing and Clearances

A. Select Appliance Location

When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1).

WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access. Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

NOTICE: Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. Illustrations/diagrams are not drawn to scale. Actual installation may vary due to individual design preference.

1/2 in. (13 mm) min. appliance

to combustibles

 

D

1 in. (25 mm)

 

min. pipe to

 

 

B

1/2 in. (13 mm) min.

combustibles

C

appliance to

 

 

combustibles

 

B

Drywall

A

Top Vent

One 90° elbow

Horiz Term

A

G

Alcove

Installation

48 in.

(1219 mm)

maximum

AD

Rear vent

One 45° elbow Horiz Term

In addition to these framing dimensions, also reference the following sections:

Clearances and Mantel Projections (Sections 3.C. and 3.D.)

Vent Clearances and Framing (Section 6)

Rear Vent

One 90° elbow

A Vert Term

E

1 in. (25 mm)

 

min. pipe to

E

combustibles

No elbows

Horiz Term

A

Rear Vent

 

Two 90° elbows

A

Horiz Term

F

C

F

Model

 

A

B

C

D

E

F

G

NNXT3933

in.

39

35-1/2

19-5/8

43-3/8

47

53-1/4

40

mm

991

902

498

1102

1194

1353

1016

 

NNXT4236

in.

42

37-5/8

19-5/8

43-3/8

47

53-1/4

43

mm

1067

956

498

1102

1194

1353

1092

 

Figure 5.1 Appliance Locations