Heatiator NNXT3933IL Power Outage, Manual Fireplace Shutoff, Turn off the control module

Models: NNXT4236I NNXT4236IL NNXT3933I NNXT3933IL

1 82
Download 82 pages 55.73 Kb
Page 57
Image 57

Power Outage

If fireplace battery backup system IS installed at time of power outage, fireplace operation will not be interrupted.

If fireplace battery backup system IS NOT installed at time of power outage, fireplace will shut off. To resume fireplace operation, install battery backup.

NOTICE: Battery polarity must be correct or module damage will occur.

Manual Fireplace Shutoff

In the unlikely event that the remote wall switch malfunc- tions and will not turn off the fireplace, call your dealer for service assistance. In the meantime, you may choose one of the following actions to turn off the fireplace:

CAUTION! Risk of burns! Fireplace surfaces are hot when operating and during cool down. Use care and wear gloves when opening the front and accessing compo- nents inside the fireplace.

Frequently Asked Questions/Troubleshooting

The fireplace may be manually shut down by one of the following methods:

Turn off the control module:

Open or remove the decorative front to access the control module.

Move switch to OFF (See Figure 6).

Disconnect power to the control module:

Open or remove the decorative front to access power cord to the junction box and/or back-up batteries.

Unplug the control module and/or remove back-up batteries.

Shut off gas to the control:

Open or remove the decorative front and locate the gas shut-off valve to the left of the gas control.

Rotate the valve 90 degrees to turn off gas supply.

Turn off power to the fireplace (if back-up batteries are not installed):

Locate house circuit breaker for fireplace.

Turn off the circuit breaker.

Symptom

Possible Cause

Corrective Action

 

Batteries

Verify battery is functional and installed correctly.

Remote control will not transmit

Remote control is in Child

Disengage Child Lock mode.

 

Lock mode

 

 

 

Control module is not in

Ensure module switch is set to REMOTE.

 

“REMOTE” mode

 

 

 

Control module and remote

The control module will beep when it successfully receives a

 

control are not programmed

command. If it does not beep, clear module memory and re-

Control module will not take

to each other

program wall switch.

commands from remote control

 

 

Control module is

If red LED light comes on when power button is pressed, verify

 

 

unplugged. In case of

that the control module is plugged in the fireplace junction box

 

power outage, backup

located in the controls area. Also verify that the batteries are

 

batteries are depleted or

installed in the battery pack.

 

missing

 

Fan does not turn on when fireplace

Built in time delay

The fireplace must run for seven minutes in order for the fan

is started

to engage.

 

Fan does not turn off when fireplace

Built in time delay

The fan will run for twelve minutes after the fireplace is turned off.

turned off

 

 

Fireplace shuts down after extended

 

The fireplace will automatically shut down after nine hours of

Built-in timer

continuous operation if it does not receive a command from

periods

 

the remote.

 

 

 

 

The fireplace cannot be turned off by remote if an external

 

External wired wall switch

wired wall switch is installed and in the ON position. Turn ex-

Fireplace is on but will not shut off

 

ternal wall switch to OFF.

with the remote control

Remote control or control

At control module, turn off fireplace by sliding the ON/OFF/RE-

 

MOTE switch to OFF. Warning! Risk of Fire! Fireplace is hot.

 

module failure

 

Use caution when accessing module.

 

 

 

 

Please contact your Hearth & Home Technologies

 

 

dealer with any questions or concerns.

 

 

For the location of your nearest

 

 

Hearth & Home Technologies dealer,

 

 

please visit www.fireside.com.

Heatilator • Novus NNXT • 4055-879 • Rev. o • 2/12