3-4. SPECIAL PROGRAMMING MODES (Continued)
3-5. ONE STEP KFC PARAMETERS
3.Select the desired special function by depressing either cycle switch 6 or 7.
4.Perform the desired operation.
5.Depress the EXIT FILL switch to exit the special program mode. Unit will return to
The preceding steps must be followed exactly to enter the special program mode.
1.Enter the special program mode.
2.Depress the cycle 6 switch. Display will read as follows.
Digit 4 3 2 1
Digit 1: Blank - When depressed it will erase all memory from controller. Display will read INIT for one second then erase all memory.
Digit 2: Blank - When depressed it will enter all KFC cooking parameters. Display will read INIT for two seconds, then DEF for two seconds.
Digit 3: Display will read either F for Fahrenheit degrees or C for Celsius degrees.
Digit 4: Display will read either E for Electric or 0 for other (includes gas).
1.Enter the special program mode.
2.Depress the cycle 7 switch. Display will be blank.
3.Depressing a certain switch on the front panel turns an output on, while depressing the same switch again turns that output off. This will test all circuits on the controller.
304 |