3-6. TEST PROCEDURE (Continued)

3-6. TEST PROCEDURE (Continued)

The table below shows the corresponding switch with the output.

Switch

DeviceActivated

Product One

Pressure Solenoid and Heat Control

Select Time

Product Indicators

Select Function

Function Indicators

Change Switch Under Display 4

Change Switch Indicator Display

Change Switch Under Display 3

Change Switch Indicator Display

Change Switch Under Display 2

Change Switch Indicator Display

Change Switch Under Display 1

Change Switch Indicator Display

The SELECT FUNCTION or SELECT TIME switch must be depressed before the PRODUCT ONE switch to properly perform the solenoid and heat control output test.

3-7. SPECIAL FUNCTIONS

3-4

To avoid personal injuries or property damage when performing the solenoid and heat control test, be sure there is shortening in the frypot. Unit will run unregulated. For test purposes only.

When programming one step KFC parameters, load compen- sation, proportional control, and filter cycle are automatically programmed into the control. The following defines these three functions.

Load Compensation - Load compensation adjusts cooking times to compensate for differences in the cooking process such as load size. The control is continuously comparing the pot temperature to the setpoint, the control will shorten the cook time. If the pot temperature is below the setpoint, the control will lengthen the cook time. Load compensation for KFC parameters is set at 0.

Proportional Control - Proportional control regulates pot tempera ture by pulsing the heat off and on until it reaches setpoint tempera ture. This allows better temperature accuracy when dropping product. Proportional control for KFC parameters is set at

10 degrees.

Filter Cycle - Filter indication is given after the programmed

 

number of cycles are cooked. KFC parameters are set at 1,

 

and further operation of the control is not allowed until filtering

 

is complete.