Henny Penny FM07-020-F manual Slot Cover, Control Panel Installation

Models: FM07-020-F

1 40
Download 40 pages 58.46 Kb
Page 8
Image 8
1-7. SLOT COVER

1-7. SLOT COVER

When installing the computerized panel retrofit kit, it is necessary

 

to cover the existing slot in the heat shroud. This slot allows the

 

capillary tube of the old control panel to extend through the heat

 

shroud when mounting the old control.

 

A. Open door and push slot cover through shroud from bottom

 

of the shroud.

 

B. Bend the 4 tabs of slot cover over the top of the heat shroud.

1-8. CONTROL PANEL INSTALLATION

A.The new computerized panel is positioned and installed exactly like the existing electromechanical control panel.

B.Place the computerized control panel on top of fryer frame and door.

C.Mate the nine-pin connectors together. Refer to KFC gas wiring diagram.

D.Connect the temperature probe to the control panel board.

E.Install the control panel and two screws. When installed properly there will be approximately a 7/16 inch of a gap between the bottom of the control panel and fryer rail.

F.This completes the electrical and mechanical installation of

the computerized control panel.

1-4