1-5. NINE-PIN CONNECTOR WIRING

1-5. NINE-PIN CONNECTOR WIRING

1-6. TEMPERATURE PROBE INSTALLATION

A.Remove the above wires from their existing position. These wires will be connected to the nine-pin connector provided.

B.Locate wires number 12, 8, and 11 at the fan motor. Remove the connector securing these wires. Wire number 11 can be discarded at this time. Wire number 12 will be connected to the nine-pin connector as noted on the wiring diagram. Wire number 8 from the fan motor will be joined with wire number 15 before it is connected to the nine-pin connector. Join these two wires using the twist-on wire connector provided.

C.Note the position of the wires on the nine-pin connector. Reference wiring diagram Figure 2. The wires on the connector will have corresponding numbers to those within the control panel.

D.Using the twist-on wire connectors provided, splice the corresponding wires together.

E.Wiring of the nine-pin connector is completed.

“Do not install the control panel at this time.”

A.Drain the shortening from the cook pot to a level below the position of the thermostat pot fitting.

B.Remove the thermostat capillary tube from the cook pot

as per section 5-11 of standard Henny Penny Service Manual.

C. Install the reducer fitting, Henny Penny part number FP01-024 into the pot wall fitting. Use pipe sealant to seal the pipe threads.

D. Install the compression fitting, part number 30094, Figure

3 into the reducer. Use pipe sealant to seal the pipe threads.

E.Install the new probe by inserting the probe into the compression fitting until the probe extends one-half (1/2) inch into the cook pot. Tighten the nut on the compression fitting a half a turn past the point where the fitting first becomes tight onto the probe.

Excess force will damage the probe.

F. Installation of the temperature probe is complete.