Shortening | will | Faulty | Contactor | Check contactor | per Section |
|
not heat, but | (elec. model) |
|
|
| ||
lights are | on. | Faulty | Thermal | Check thermal sensor per Section | message” E6. | |
|
| |||||
|
| Sensor |
|
|
|
|
|
| Faulty | High | Check high limit | control switch per Section | |
|
| Limit |
|
|
|
|
A. Pilot will not | Pilot | not | lit |
| * Light | pilot per Section | |
light (gas model) | Plugged | pilot | * Unplug pilot orifice and/or pilot supply tube. | ||||
| |||||||
| orifice, | and/or |
|
| |||
| pilot | supply | tube |
|
| ||
| Gas supply | off | Turn | ON gas supply. | |||
| Faulty | gas con- | Replace gas control valve. | ||||
| trol | valve |
|
|
| ||
| Air | in gas supply | Bleed | air from supply line. | |||
| line |
|
|
|
|
|
|
B. Pilot will not | Faulty therm0 | Replace therm0 couple per Section |
stay lit. | couple |
|
| Pilot magnetic | Service per Section |
C. Burner will not light, pilot li (gas model)
PlW
Drain valve | open | Close drain valve. |
|
High Limit | con- | With power removed from fryer, | check across high limit |
trol switch | open | switch terminals with ohmmeter. | Replace if no reading is |
|
| indicated on meter. |
|
Possible faulty | With power removed from fryer, | check across electrical | |
gas control | valve | leads of gas control valve with ohmmeter, and gas valve in | |
|
| “ON” position. Ohm reading should be 234 ohm resistance. | |
|
| Replace the control valve if not within 10%. |