Appendix: Installation
2. INSTALLATION LOCATION
2.1 Indoor unit
Maintain the required space
!WARNING around the appliance to
prevent overheat.
The location for installation of the appliance should not be in an area with the following:
Di rect sunlight
H eat resource
Inflammable gas
Thick oil fog
The appliance should be installed in an area,
Where the inside space can be evenly conditioned, or
Which is strong enough for the appliance, or,
Having the shortest distance for the copper tubes and water drain hose, and
Having desired space around the appliance for maintenance and ventilation.(Figure 1)
|
|
| Min. 5cm |
|
|
| Min. 5cm | Min. 5cm | |
|
| Figure 1 |
| |
Tube arrangement |
|
| ||
L | H | Added Refrigerant | Provided Tube(M) | |
|
| (g/m) |
|
|
15 | 7 | 20 |
| 4 |
L:Maximum length of the tube connecting the indoor unit and the outdoor unit.
H:The height difference between the indoor unit and the outdoor unit.
Tube length(L)
Indoor unit
Height difference(H) | Outdoor |
| unit |
Figure 2
*If the length of the tube is exceed 7m, an additional 20g/m of refrigerant should be added per 1m.
2.2 Outdoor unit
The outdoor unit should be installed away from the following: Heat source and fan exhausting (Figure 3);
Director sunlight;
8
Figure 3
The outdoor unit should be installed in an area with, Cool temperature;
Good ventilation;
Desired space for air inlet, outlet and maintenance (Figure 4)
|
|
| Top obstacle |
|
Air inlet | Min. 10cm |
|
| 2m |
| Valve side | outletAir | 2m | |
| Min. 25cm |
| ||
|
|
| Obstacle | |
Min. 10cm | Air outlet |
|
| |
| Min. 40cm |
|
|
|
Figure 4
Ground Min.10cm
Air inlet
Strong base (10x10cm2 concrete or alike). The appliance should be placed not less than 10cm high (Figure 5).
Firm bolts(4)
Air inlet
Min. 10cm
Concrete or alike
Abo |
|
|
|
| 10cm |
|
|
|
| ||
ut | 4 |
| About | ||
| |||||
|
| 0cm | |||
|
|
|
!
WARNING
The indoor unit should not be | Fix the base with firm bolts to reduce vibration and noise. |
|
installed below a height of 1.8m.
23