2. INSTALLATION LOCATION

Appendix: Installation

2. INSTALLATION LOCATION

2.1 Indoor unit

Maintain the required space

!WARNING around the appliance to

prevent overheat.

The location for installation of the appliance should not be in an area with the following:

2.1 Indoor unit Di rect sunlight

Maintain the required space H eat resource

!WARNING around the appliance to Inflammable gas

2.2 Outdoor unit Thick oil fog

The appliance should be installed in an area,

The indoor unit should not be Where the inside space can be evenly conditioned, or

installed below a height of 1.8m. Which is strong enough for the appliance, or,

Manual background Having the shortest distance for the copper tubes and water drain hose, and

Manual background Having desired space around the appliance for maintenance and ventilation.(Figure 1)

 

 

 

Min. 5cm

 

 

 

Min. 5cm

Min. 5cm

 

 

Figure 1

 

Tube arrangement

 

 

L

H

Added Refrigerant

Provided Tube(M)

 

 

(g/m)

 

 

15

7

20

 

4

L:Maximum length of the tube connecting the indoor unit and the outdoor unit.

H:The height difference between the indoor unit and the outdoor unit.

Tube length(L)

Indoor unit

Height difference(H)

Outdoor

 

unit

Figure 2

*If the length of the tube is exceed 7m, an additional 20g/m of refrigerant should be added per 1m.

2.2 Outdoor unit

The outdoor unit should be installed away from the following: Manual background Heat source and fan exhausting (Figure 3);

Manual background Director sunlight;

8

Figure 3

The outdoor unit should be installed in an area with, Manual background Cool temperature;

Manual background Good ventilation;

Manual background Desired space for air inlet, outlet and maintenance (Figure 4)

 

 

 

Top obstacle

 

Air inlet

Min. 10cm

 

 

2m

 

Valve side

outletAir

2m

 

Min. 25cm

 

 

 

 

Obstacle

Min. 10cm

Air outlet

 

 

 

Min. 40cm

 

 

 

Figure 4

Ground Min.10cm

Air inlet

Manual background Strong base (10x10cm2 concrete or alike). The appliance should be placed not less than 10cm high (Figure 5).

Firm bolts(4)

Air inlet

Min. 10cm

Concrete or alike

Abo

 

 

 

 

10cm

 

 

 

 

ut

4

 

About

 

 

 

0cm

 

 

 

!

WARNING

The indoor unit should not be

Fix the base with firm bolts to reduce vibration and noise.

 

installed below a height of 1.8m.